Coleman 5400 LP manual Cleaning the Venturi, Representative Illustration, Cleaning and Maintenance

Models: 5400 LP

1 40
Download 40 pages 60.11 Kb
Page 32
Image 32
Cleaning the Venturi

Cleaning the Venturi

Steps For Cleaning Venturi:WARNING

Spider’s nests or wasp’s mud inside the venturi may cause fire at valve. If a fire occurs, immediately turn off gas supply at L.P. cylinder valve (see representative illustration in Fig. 22). If your grill is set up for use with Natural Gas, turn off gas supply at the system manual shut off valve.

Note:

Spiders and small insects can spin webs and build nests inside the venturi tubes. This especially occurs in late summer and fall before frost when spiders are most active. These nests can obstruct gas flow and cause a fire in and around the burner valves. Such a fire can cause operator injury and serious damage to the grill. To help prevent a blockage and ensure full heat output, clean and inspect venturi tubes often (once or twice a month). NOTE: Water or air pressure will not normally clear a spider web.

Steps For Cleaning Venturi:

1.Remove burner from grill bottom.

2.Look inside lower end of venturi tubes for nests, webs or mud.

3.To remove the above obstructions, use an accessory flexible venturi brush or bend a small hook on one end of a 20-inch- long flexible wire such as the one shown in Fig. 23.

4.Inspect and clean the burner if needed.

5.Replace the burner assembly into the grill.

6.Make sure the valve orifices are inside the venturi tubes.

7.Secure burner back into grill bottom.

22

REPRESENTATIVE ILLUSTRATION

23

32

Cleaning and Maintenance

REPRESENTATIVE ILLUSTRATIONCAUTION

All cleaning and maintenance should be done only when grill is cool & with the fuel supply turned off at the cylinder. If your grill is set up for use with Natural Gas, turn off gas supply at the system manual shut off valve.

Suggested Cleaning Materials:

Mild dishwashing liquid detergent

Hot water • Wire brush

Paper clip •

Nylon cleaning pad

Soft brass-bristled brush

Putty knife

• Scraper

 

 

Component Cleaning:

BURNER: Wire-brush loose corrosion from burner exterior. Clean clogged gas port holes with an opened paper clip. Replace corroded or damaged burners that would emit excess gas.

STAINLESS STEEL: Clean with any multipurpose (low abrasive, no phosphorous) metal polish or stainless steel polish and a soft cloth to prevent marring or scratching the surface. NEVER USE OVEN CLEANER!

ORIFICES: Unscrew orifices from rear of valves (Fig. 24). Wash orifices in solvent and blow air through the small end holes. Carefully replace the orifices in valve when they are dry. Make certain that orifices are tightly reassembled.

Page 32