About the M110

Environmental Requirements

To operate the system efficiently and safely, install and maintain the Omvia Media Server M110 in a room with the appropriate temperature and humidity.

The recommended location for the system is an office environment with low dust content and an effective cooling and ventilation system. Install the system within 5 feet of electrical outlets. A typical location is in the room containing centralized telephone cabling, or near the PBX used by the system.

Equipment Installation

Do not install the equipment in direct sunlight. Direct sunlight can cause the system to overheat.

Specifications

The environmental, dimension, and power specifications for the M110 are listed below:

Table 2-1. M110 Specifications

Specification

Properties

 

 

Storage Environment

-40° C to 65° C or -40° F to 149° F

 

5% to 95% non-condensing humidity

 

 

Operating Environment

10° C to 35° C or 50° F to 95° F

 

8% to 80% humidity

 

 

Altitude

Storage environment: 35,000 ft. maximum

 

Operating environment: 10,000 ft. maximum

 

 

Dimensions

17.6” W x 27.0” D x 1.67” H

 

 

Weight

35 lbs.

 

 

Power

• Optional, hot plug, redundant 275 Watts power

 

supplies

 

• 110/220 Volts

 

-48v DC power supply option

 

 

60001024, Third Edition