SONOSAX SX/S USER MANUAL

Seite 17 von 22

To make the external slate Mic operational you will need to solder in R-7=15kOhms (R-5=49.9) and C-11=22pF remove R-10 on the extension module operator board. Unsolder the internal mic on Connectors J-10 & J-11.

Then connect J-12 to the Bantam jack. Make sure that Jumper 2 is in position 2,3.

NOTE: The internal Slate Mic is deactivated by this procedure.

SX-S10 only: Remove the unused wire on the Bantam connector.

7.4 Y Cables for Boom Operator with tbk mic transmitter.

Click here for DIAGRAMof "Y" Cable

Internal connections of the Boom-Box (022260)

Click here for BOOM BOX Wiring Diagram

 

860162

 

860179

 

 

860141

Pin No

Cable

Pin No

Cable

Pin

 

 

 

 

1

White

Tip

White

 

 

 

2

White

Ring

Red

1

GND

Black

3

White

GND

GND

3

White

Black

4

 

 

 

2

Red

Black

5

 

 

 

 

 

 

6

 

 

 

922110 External cable between SX-S extension module and SX-S extension box

Click here for MALE and FEMALE Socket Wiring

Pin No

Pair No

Cable

Designation

12

4

Shield

GND

11

4

White

-12V

10

4

Yellow

+12V

9

3

Orange

Guest

8

3

White

Roll

7

3

Shield

12V micro

6

2

Red

Right from Ext. Box

5

2

White

Left from Ext. Box

4

2

Shield

GND from Ext. Box

3

1

Brown

Right to Ext. Box

2

1

White

Left to Ext. Box

1

1

Shield

GND to Ext. Box

RETURN TO TABLE OF CONTENTS