SONOSAX SX/S USER MANUAL

Seite 8 von 22

input pre-amplifier.

3.15 Line out connectors

Same Mini-Jacks as INSERT connectors. Independent asymetrical output. One of the contacts gives the modulation before fader (PRE) and the other after the fader (POST).

3.16Input module configuration

RETURN TO TABLE OF CONTENTS

4. STANDARD INPUT MODULE

Differences from the newer Power / Mute modules

4.1 Power on/off push-button (red knob)

Each input module is equipped with an ON/OFF switch (red knob) in order to optimize power consumption, if all inputs are not used.

WARNING: Do not switch on an input module during a sound recording as this causes a pop.

Optional MUTE push button (gray knob), replaces Power on/off: supplies constant module powering. The gray knob turns modulation on and off silently ( no pops).

4.2 30 dB PAD (Input attenuator)

To be switched on when the OVD LED lights up at minimum gain control setting. This happens, for instance, when high level input sources such as a tape recorder or a condenser microphone at high acoustic levels are used.

4.3 GAIN

file://D:\Z_Library\Webcopy\sonosax\SXS\sxsume.html

26.08.2004

Page 8
Image 8
Compex Systems SX-V, SONOSAX SX-S user manual Seite 8 von, Standard Input Module