8. BIOS Setup
SPI-8451-LLVA, SPI-8452-LLVA, SPI-8451-LVA 109
RAM parity error
CHECKING FOR SEGMENT ...
Indicates a parity error in Random Access Memory.
Should be empty but EISA board found
PLEASE RUN EISA CONFIGURATION UTILITY
A valid board ID was found in a slot that was configured as having no board ID.
NOTE; When this error appears, the system will boot in ISA mode, which allows you to
run the EISA Configuration Utility.
Should have EISA board but not found
PLEASE RUN EISA CONFIGURATION UTILITY
The board installed is not responding to the ID request, or no board ID has been found in the indicated
slot.
NOTE: When this error appears, the system will boot in ISA mode, which allows you to
run the EISA Configuration Utility.
Slot not empty
Indicates that a slot designated as empty by the EISA Configuration Utility actually con-tains a board.
NOTE: When this error appears, the system will boot in ISA mode, which allows you to
run the EISA Configuration Utility.
System halted, (CTRL-ALT-DEL) to REBOOT …
Indicates the present boot attempt has been aborted and the system must be rebooted. Press and hold
down the CTRL and ALT keys and press DEL.
Wrong board in slot
PLEASE RUN EISA CONFIGURATION UTILITY
The board ID does not match the ID stored in the EISA non-volatile memory.
NOTE: When this error appears, the system will boot in ISA mode, which allows you to
run the EISA Configuration Utility.
Floppy disk(s) fail (80)
Unable to reset floppy subsystem.
Floppy disk(s) fail (40)
Floppy Type mismatch.
Hard disk(s) fail (80)
HDD reset failed.
Hard disk(s) fail (40)
HDD controller diagnostics failed.