Continental BCDV42P manual Air Terminal Installations, A B C D E F G H I J K L M N O, Feet‡, U.S.A

Models: BCDV42N BCDV42P

1 28
Download 28 pages 7.94 Kb
Page 6
Image 6
AIR TERMINAL INSTALLATIONS

6

AIR TERMINAL INSTALLATIONS

FIGURE 2

INSTALLATIONS

A B

C

D

E

F

G

H

I

J

K

L

M

N

O

CANADIAN

12INCHES

12INCHES

12 INCHES*

32INCHES**

32INCHES**

0 INCHES

0INCHES***

2 INCHES***

3FEET

3FEET 12 INCHES 6 FEET

7 FEET‡

32INCHES†† 16 INCHES 2 FEET†*

U.S.A.

12INCHES 9 INCHES

12 INCHES*

32INCHES**

32INCHES**

0 INCHES

0INCHES***

2 INCHES***

3FEET****

3FEET****

9 INCHES

3 FEET†

7 FEET****

32INCHES**** 16 INCHES 2 FEET†*

Clearance above grade, veranda porch, deck or balcony.

Clearance to windows or doors that open.

Clearance to permanently closed windows.

Vertical clearance to ventilated soffit located above the terminal within a horizontal distance of 2 feet from the centerline of the terminal.

Clearance to unventilated soffit.

Clearance to an outside corner wall.

Clearance to an inside non-combustible corner wall or protruding non-combustible obstructions (chimney, etc.).

Clearance to an inside combustible corner wall or protruding com- bustible obstructions ( vent chase, etc.).

Clearance to each side of the centerline extended above the meter

/regulator assembly to a maximum vertical distance of 15ft. Clearance to a service regulator vent outlet.

Clearance to a non-mechanical air supply inlet to the building or a combustion air inlet to any other appliance.

Clearance to a mechanical air supply inlet.

Clearance above a paved sidewalk or paved driveway located on public property unless fitted with a heat shield kit GD-301.

Clearance under a veranda, porch, deck or balcony.**

Clearance above the roof.

Clearance from an adjacent wall including neighbouring buildings.

*Recommended to prevent condensation on windows and thermal breakage

**Using a Napoleon soffit heat shield, W585-0096, or equivalent, the distance may be reduced to a minimum of 18". It is recommended to maximize the distance to vinyl clad soffits.

***The periscope GD-401 requires a minimum 18 inches clearance from an inside corner.

****This is a recommended distance. For additional requirements check local codes.

Three feet above if within 10 feet horizontally.

A vent shall not terminate directly above a sidewalk or paved driveway that is located between two single family dwellings and serves both dwellings.

††Permitted only if the veranda, porch or deck is fully open on a minimum of two sides beneath the floor.

†* Recommenced to prevent recirculation of exhaust products. For additional requirements check local codes.

W415-0385 / A / 10.02.03

Page 6
Image 6
Continental BCDV42P manual Air Terminal Installations, A B C D E F G H I J K L M N O, INCHES 2 INCHES 3 FEET, Feet‡, U.S.A