Continental BCDV42N Typical Vent Installations, Special Vent Installations, Periscope Termination

Models: BCDV42N BCDV42P

1 28
Download 28 pages 7.94 Kb
Page 7
Image 7
TYPICAL VENT INSTALLATIONS

7

TYPICAL VENT INSTALLATIONS

NOTE:

When terminating vertically, the restrictor plate W500-0205 must be installed. Refer to Restricting Vertical Vents.

FIGURES 3 a-c

SPECIAL VENT INSTALLATIONS

PERISCOPE TERMINATION

Use the GD401 periscope kit to locate the air termination above grade. The periscope must be installed so that when final grading is completed, the bottom air slot is located a minimum of 12 inches above grade. The maximum allow- able vent length depends on the fireplace, as illustrated.

FIGURE 4

W415-0385 / A / 10.02.03

Page 7
Image 7
Continental BCDV42N, BCDV42P Typical Vent Installations, Special Vent Installations, Periscope Termination, FIGURES 3 a-c