ADJUSTMENTS

23

ADJUSTMENTS

PILOT BURNER ADJUSTMENT

Adjust the pilot screw to provide properly sized fl ame. Turn in a clockwise direction to reduce the gas fl ow.

FIGURE 55

FIGURE 56

VENTURI ADJUSTMENT

Air shutters have been factory set open according to the chart below: PILOT BURNER ADJUSTMENT

 

FRONT

REAR

NG

1/8"

7/32"

LP

3/16"

3/8"

These settings are for the maximum horizontal vent run.- Adjust- ment may be required depending on fuel type, vent confi guration and altitude.

Closing the air shutter will cause a more yellow fl ame, but can lead to carboning. Opening the air shutter will cause a more blue fl ame, but can cause fl ame lifting from the burner ports. The fl ame may not appear yellow immediately; allow 15 to 30 minutes for the fi nal fl ame colour to be established.

FIGURE 57

Air shutter adjustment must only be done by a qualified

installer!

FIGURE 58

VENTURI COVER

To access the air shutter, remove the two screws that secure the cover to the air housing, taking care not to damage the gasket.

NOTE: Ensure burner is seated onto orifi ce