Continental CVF36N Finishing, Grate And Log Installation, Hood Curtain Mesh, Charcoal Embers

Models: CVF36N CVF36P

1 18
Download 18 pages 47.43 Kb
Page 8
Image 8
FINISHING

8

FINISHING

GRATE AND LOG INSTALLATION

1.Remove curtain mesh and rod assembly

2.Remove log carton

3.Remove grate from the lower control area (stored there when shipped)

4.Unscrew the 3 screws in the fi rebox, set grate in place and secure using the 3 screws that were just removed.

See Figure 11.

5.Install the one piece logset by aligning the two holes on the bottom of the logs, with the two locating pins in the

rebox.

NOTE: PHAZERTM logs and glowing embers exclusive to Continental® Fireplaces, provide a unique and realistic glowing effect that is different in every installation. Take the time to carefully position the glowing embers for a maximum glowing effect.

Log colours may vary. During the initial use of the fi replace, the colours will become more uniform as colour pigments burn in during the heat activated curing process.

6.Reinstall rod assembly and mesh curtain

FIGURE 10

HOOD

FIGURE 11

HOOD

CURTAIN

MESH

The curtain mesh must be kept fully closed during operation to help prevent accidental burns from occurring.

FIGURE 12

CHARCOAL EMBERS

Randomly place the charcoal embers along the front and sides of the log support tray in a realistic manner. Fine dust found in the bottom of the bag should not be used.

The heater must not be used when the hood is re- moved. Hook the hood over the lip of the curtain support plate.

LOGO PLACEMENT

GLOWING EMBERS

Tear the embers into pieces and place along the front row of ports covering all of the burner area in front of the small logs (#2 & #3). Care should be taken to shred the embers into thin, small irregular pieces as only the exposed edges of the fi bre hairs will glow. The ember material will only glow when exposed to direct flame; however, care should be taken to not block the burner ports.

Blocked burner ports can cause an incorrect fl ame pattern, carbon deposits and delayed ignition. PHAZERTM logs glow when exposed to direct fl ame. Use only certifi ed “glowing embers” and PHAZERTM logs available from your Continen- tal® dealer.

Remove the backing of

the logo supplied and FIGURE 13 place on the screen

cover, as indicated.

W415-0298 / K / 12.06.07

Page 8
Image 8