FIGURE 19
Attach the connectors from the black and red wires to the blower.
Attach and secure the variable speed switch using the nut provided. Plug the harness cord into the receptacle.
FIGURE 20
The wire harness provided in this kit is a universal harness. When installed, ensure that any excess wire is contained, preventing it from making con- tact with moving or hot objects.
Because the blower is thermally activated, when turned on, it will automatically start approximately 10 minutes after lighting the fireplace and will run for approximately
Drywall dust will penetrate into the blower bear- ings causing irreparable damage. Care must be taken to prevent drywall dust from coming into contact with the blower or its compartment. Any damage resulting from this condition is not cov-
FIGURE 22
Slide the fan assembly past the controls and into the clip. Secure using the lock washer and nut provided. Plug the har- ness cord
into the re- ceptacle.
GD36 THERMOSTATIC SENSOR
CONTROL
This optional kit is meant to be used only in conjunction with the GD65 Fan Kit, which may be ordered from your Wolf Steel /Continental® dealer.
With the thermostatic sensor option, the fan, when turned on, becomes thermally activated, and will automatically run approximately 10 minutes after the fi replace has been lit and for approximately
Use of the fan increases the output of heat.
If optional thermostatic sensor kit is to be installed, remove thermodisc from the bracket supplied in the kit and disgard the bracket. Install thermodisc in the bracket supplied with the
fireplace. It is recommended to attach the wires to the disc and install the bracket before installing the blower. Attach the black and white wires to the disc, then secure the bracket to the stud at the bottom left on the unit using the lock washer and wing nut. Ensure that the thermodisc touches the fi rebox
ered by the warranty policy.
GD65 FAN INSTALLATION
ELECTRICAL INSTALLATION TO BE DONE BY A QUALI- FIED INSTALLER and must be connected and grounded in accordance with local codes. In the absence of local codes, use the current ANSI/NFPA 70
NATIONAL ELECTRICAL CODE.
wall.
Unplug the power cord f r o m t h e receptacle. C o n n e c t all wires as shown.
FIGURE 23
If the fireplace was not previ- ously equipped with a blower,
route a grounded
The wire harness provided in this kit is a universal harness. When installed, ensure that any excess wire is contained, pre- venting it from making contact with moving or hot objects.
Position the vibration reducing pad into the clip and onto the threaded stud at the other end, piercing a hole into the pad. The fan assembly must be able to be positioned entirely onto the pad.
P l u g t h e
power cord back into the receptacle.
When installed, ensure that any excess wire is contained, pre- venting it from making contact with moving or hot objects.
FIGURE 24