How to operate your fixture

Step 5: Your motion sensor may be wall or ceiling mounted. Position motion sensor a minimum of 3” away and below your existing light. Do not pull the coiled cord too tight. Make sure sensor head is positioned with control switches facing towards the ground and that the slots in the mounting plate are also facing the ground. Attach the mounting plate with the two screws provided.

Step 6: Plug the coiled cord connector into the bottom of the motion sensor. Either slot may be used.

Step 7: Turn power on at the main fuse/breaker box.

NOTE: The motion sensor is equipped to control two adapters. If you are connecting to a twin floodlight, another adapter may be added to create a twin par motion-activated floodlight.

How to operate your fixture

Step 1: Move slide switch on bottom of the sensor to “TEST”. Set sensitivity knob to medium (halfway) (E).

Step 2: Turn on the power to fixture. Lights will turn on for approximately 40 seconds, then lights will blink off, on, off, on and off. The motion sen- sor is now ready to detect motion.

Step 3: Aim sensor head in desired position. NOTE: Maintain air spacing between lamps and sensor head, at least 3”. Make sure sensor head is positioned with control switches facing towards the ground.

E

TEST 4 MIN 12 MIN SENSITIVITY

THIS IS THE

BOTTOM SIDE OF THE MOTION DETECTOR

Step 4: Walk across the detection zone at the farthest distance you wish your detector to detect motion.

Step 5: Adjust sensitivity until you get desired results. For more range, aim sensor head slightly upwards. For less range, aim sensor head slightly downward. Lights will turn off 4 seconds after all motion stops. NOTE: For maximum range performance, allow fixture to operate in any mode (with power to the unit) for at least 48 hours.

Step 6: Move slide switch to 4 MIN. or 12 MIN. (AUTO mode). At dusk, lights will operate in the AUTO setting.

How to select your desired feature

Mode of

Set slide switch

How to set

operation:

on sensor to:

power switch:

 

 

 

AUTO Setting

 

 

(motion activated)

AUTO 4

Keep the power to

Lights should turn on with

or

the fixture on.

motion only at night and

AUTO 12

 

should turn off after

 

4 or 12 minutes.

 

 

 

 

 

Manual Override

 

 

Lights should stay on continu-

TEST

 

ously. It will then reset to

Turn power on and off

AUTO 4

“TEST Setting”or “AUTO

twice within 3 seconds.

or

Setting” after 8 hours or you

 

AUTO 12

 

can reset manually by turning

 

 

 

power on and off twice within

 

 

3 seconds.

 

 

 

 