Cooper Lighting IMI-685 installation instructions Sheet 4 of, Tribute, Installation Instructions

Models: IMI-685

1 4
Download 4 pages 40.68 Kb
Page 4
Image 4
Sheet 4 of 4

INSTALLATION INSTRUCTIONS

IMPORTANT: READ CAREFULLY BEFORE INSTALLING FIXTURE.

Tribute

Sheet 4 of 4

1/7/08IMI-685

6.Light Distribution Some of the reflector options are directional oriented. The reflector can be rotated in 90° increments. Loosen reflector mounting screws and rotate reflector to desired orientation and then retighten the mounting screws. FIG. 6. Tools required 1/4" socket.

7.Wiring

Important: Dual voltage and multi-tap ballasts are factory-wired for 277V input. Before installation make certain supply and ballast voltages are compatible. For use with other line voltages, remove wire nut splicing the black lead from the quick disconnect plug and 277V lead from ballast. Cap off 277V lead with wire nut. Splice black lead from the quick disconnect plug with desired voltage lead from ballast.

Wire leads are to be routed from housing to pole. All wiring connections are to be made in the pole. Wire the fixture voltage leads to the supply voltage lead; fixture common lead to the supply neutral lead; and the fixture ground lead to the supply ground lead. If fixture is supplied with the ballast tray option, re-connect the polarized plug and replace the ballast tray.

8.Photocontrol Receptacle Loosen the two flathead screws to allow rotation of the receptacle. Insert screwdriver into center slot and rotate receptacle until indicator arrow points north. Retighten screws. Plug the photoelectric control into receptacle and twist into locked position.

The photocontrol must contain a soft, resilient gasket fastened to the bottom surface to assure a proper weather seal between the control and the receptacle.

NOTE: The orientation procedure is only required for photocontrols which specifically require the cell to be aimed north. Otherwise factory orientation will work. Follow the directions recommended by the supplier of the photocontrol for proximity to light sources. Lighted signs, building surface reflection, floodlights, tree branches, etc. May affect final position of the photocontrol. FIG. 7

9.Lamp installation Open fixture door. Install the lamp by grasping it close to the base and rotating clockwise, tightening securely to engage socket center contact. Close the fixture door.

NOTE: Do not use lubricants on lamp base or socket as this will cause damage and void warranty.

10.Reflector and Lens Cleaning Open fixture door, dust reflector with soft, clean dry cloth. Do not use alkaline or acidic cleaners on reflector surfaces. Clean lens with non-abrasive glass cleaning solution.

NOTE: A regular maintenance schedule should be followed to retain optimal light output and reduce heat retention.

FIG. 6

FIG. 7

Loosen

These instructions do not claim to cover all details or variations in the equipment, procedure, or process described, nor to provide directions for meeting every possible contingency during installation, operation or maintenance. When additional information is desired to satisfy a problem not covered sufficiently for user’s purpose, please contact your nearest representative.

NOTE: Specifications and dimensions subject to change without notice.

Visit our web site at www.cooperlighting.com