Cooper Lighting MPWC Photometrics, C a n d l e p o wer Distr ibution, Aver ag e Luminance

Models: MPWC

1 4
Download 4 pages 1.26 Kb
Page 4
Image 4
PHOTOMETRICS

PHOTOMETRICS

C a n d l e p o wer Distr ibution

Test No.168P167

MPWC-1/232-120-EB82-LVCP-GCO-NRLL

Lamp=(3) Lumens=2800

Spacing Criteria (0-180)=1.18 (90-270)=1.14 Efficiency=49.4%

 

 

 

 

 

Aver ag e Luminance

 

 

 

Zonal Lumen Summary

 

 

 

 

 

 

 

Deg.

0o

 

45o

90o

 

 

Zone

Lumens

%Lamp

%Luminair e

 

 

 

 

 

 

 

 

 

 

 

 

0-30

779.2

 

9.3

 

18.8

 

 

 

 

 

45

8352

 

8243

7914

 

 

 

 

 

 

 

 

 

 

 

0-40

1243.9

 

14.8

 

30.0

 

 

 

 

 

55

7815

 

7799

7343

 

 

 

 

 

 

 

 

 

 

 

0-60

2115.08

 

25.2

 

51.0

 

 

 

 

 

65

7148

 

7194

6483

 

 

 

 

 

 

 

 

 

 

 

0-90

2620.06

 

31.2

 

63.1

 

 

 

 

 

75

5948

 

5873

5162

 

 

 

 

 

 

 

 

 

 

 

90-180

1530.92

 

18.2

 

36.9

 

 

 

 

 

85

3888

 

3666

3222

 

 

 

 

 

 

 

 

 

 

0-180

4150.98

 

49.4

 

100.0

Coefficient of Utilization

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

rc

 

 

 

80%

 

 

70%

 

50%

 

30%

10%

0%

rw

 

70

50

30

10

50

30

10

50

10

50

10

50

10

0

RCR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

54

54

54

54

51

51

51

45

45

39

39

34

34

31

 

 

50

48

46

44

45

43

42

39

37

34

33

30

29

26

1

 

 

45

42

39

36

39

36

34

35

31

30

27

26

24

22

2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

41

37

33

30

35

31

29

30

26

27

23

23

21

19

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

38

32

28

25

31

27

24

27

22

24

20

21

18

16

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5

35

29

25

22

27

24

21

24

19

21

17

19

15

14

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6

32

26

22

19

25

21

18

22

17

19

15

17

14

12

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7

30

24

20

17

22

19

16

20

15

18

13

16

12

11

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8

28

21

18

15

20

17

14

18

13

16

12

14

11

10

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

9

26

20

16

13

19

15

13

17

12

15

11

13

10

09

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10

24

18

14

12

17

14

12

15

11

 

14

10

12

9

08

rc=Ceiling reflectance, rw=Wall reflectance, RCR=Room cavity ratio CU Data Based on 20% Effective Floor Cavity Reflectance.

Specifications and Dimensions subject to change without notice.

ADC041675

Fail-Safe • Customer First Center • 1121 Highway 74 South • Peachtree City, GA 30269 • TEL 770.486.4800 • FAX 770.486.4801

04/15/2007 12:56:42 PM

Page 4
Image 4
Cooper Lighting Photometrics, C a n d l e p o wer Distr ibution, MPWC-1/232-120-EB82-LVCP-GCO-NRLL, Aver ag e Luminance

FAQ

What is included in the photometrics section?

The photometrics section includes information on candlepower distribution, test number, lamp luminosity, and spacing criteria.

What is the efficiency of the MPWC-1/232-120-EB82-LVCP-GCO-NRLL model?

The efficiency of this model is 49.4%.

Where can I find contact information for Cooper Lighting's Fail-Safe Customer First Center?

The contact information for Fail-Safe Customer First Center, including address, phone number, and fax, is available at the end of the manual.