Cooper Lighting P4GE-MX Sheet 2 of, Small falcon, Installation Instructions, 1/26/05 IMI-623

Models: P4GE-MX

1 7
Download 7 pages 994 b
Page 2
Image 2
Small falcon

INSTALLATION INSTRUCTIONS

IMPORTANT: READ CAREFULLY BEFORE INSTALLING LUMINAIRE.

RETAIN FOR FUTURE REFERENCE.

Small falcon

Sheet 2 of 7

1/26/05 IMI-623

WARNING: Risk of Electric Shock. Disconnect power at fuse or circuit breaker before installing or servicing.

INSTALLATION:

Mounting: (Illustrations 1, 2, and 3)

Water tight seal at cord entry provided by others.

KNUCKLE MOUNT

TRUNION (YOKE) MOUNT

ILLUSTRATION 3

ILLUSTRATION 1

ILLUSTRATION 2

 

Knuckle Mount - Illustration 1

This luminaire is equipped with an adjustable knuckle which can be mounted directly to the 1/2" NPS access hole in the coverplate of the junction box. Route luminaire leads through the mounting hole on the coverplate. Secure coverplate to knuckle by screwing the coverplate onto the knuckle. Do not tighten locknut at this time (see aiming). NOTE: Mounting the coverplate to the junction box and then screwing the knuckle of the luminaire into the coverplate can result in twisting the wires, causing connections to break and creating a shock hazard when the power is turned on. Use wire nuts or other approved connectors to connect the black luminaire lead to the black supply lead, the white luminaire lead to the white supply lead and the bare ground luminaire lead to a suitable ground. Push wires into junction box and install the coverplate (with luminaire attached) to the junction box.

WARNING: Risk of fire and/or electric shock. Failure to follow the above mounting instructions may result in personal injury and/or property damage.

Trunion (Yoke) Mount - Illustration 2

This luminaire is provided with a trunion (yoke) which can be mounted directly on a flat surface. Use wire nuts or other approved connectors to connect the black lead from the cord to the black supply lead, the white lead from the cord to the white supply lead and the green lead from the cord to a suitable ground.

WARNING: Risk of fire and/or electric shock. Failure to follow the above mounting instructions may result in personal injury and/or property damage.

Illustration 3

WARNING: Risk of fire and/or electric shock. Trunion luminaire mounting orientation as shown in Illustration 3 is not allowed. Water entry may result causing damage to internal electrical components.

Proper trunion luminaire mounting orientation will result in a horizontal lamp orientation.

These instructions do not claim to cover all details or variations in the equipment, procedure, or process described, nor to provide directions for meeting every possible contingency during installation, operation or maintenance. When additional information is desired to satisfy a problem not covered sufficiently for user’s purpose, please contact your nearest representative.

Customer First Center • 1121 Hwy 74 South • Peachtree City, GA 30269 IMI-623 ACF050370

Page 2
Image 2
Cooper Lighting P4GE-MX Sheet 2 of, Small falcon, Installation Instructions, Mounting Illustrations 1, 2, and

FAQ

What are the mounting options for Cooper Lighting P4GE-MX?

The luminaire can be mounted using a knuckle mount or a trunion yoke mount, as illustrated in the manual.

How should the wires be connected during installation?

Wire nuts or other approved connectors should be used to connect the black, white, and green leads as specified in the manual.

What should be done to prevent water entry and damage to internal electrical components?

The luminaire must be mounted in the proper orientation as shown in Illustration 3 to prevent water entry and damage.