reclosers, fuses, tap.7 Figure diagram Connection
).shown not are arresters and

control transfer-load S Type for

 

6-PST Type the operating

 

switch

TYPE CI SWITCH

N

A

SOURCE I

B

C

 

SEE INSERT FOR

 

INTERNAL

 

CONNECTIONS

POTENTIAL

 

SENSING

L M N P R S T U V

TRANSFORMERS

500 VA MIN

L M N P R S T U V

 

120 VAC, 60 HZ

 

SECONDARIES

 

NOTE: FOR SINGLE-PHASE SENSING

JUMPER TERMINAL A TO B TO C AND

TERMINAL X TO Y TO Z ON TB2

LOAD TAP

 

 

 

 

 

 

 

 

A B C D E F G

 

 

 

 

 

 

 

 

 

A B C D E F G

 

 

 

 

 

 

 

 

 

 

 

TB5

1

2

3

4

5

6

7

8

9 10 11 12 13 1415 16 17 1819 20 21 22

 

 

 

 

 

 

 

S CONTROL

 

 

 

 

TRANSFER SWITCH OPERATORS

 

1

2

3

4

5

6

7

8

9 1011 12 13 1415 16 17 1819 20TB6

"SW"

 

 

 

 

 

 

 

 

 

"SW"

L L

 

 

 

 

 

 

 

 

 

A A

M M

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

B B

N N

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C C

P P

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D D

R R

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

E E

S S

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

F F

T T

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

G G

U U

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

H H

V V

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

J J

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

K K

 

 

POTENTIAL SENSING TRANSFORMERS

 

 

 

 

 

 

 

A B C G1 G2 X Y Z

TB2

"PT"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

"PT"

A A

 

 

 

 

 

 

 

 

 

E E

B B

 

 

 

 

 

 

 

 

 

F F

C C

 

 

 

 

 

 

 

 

 

G G

D D

 

 

 

 

 

 

 

 

 

H H

TYPE CI SWITCH

SEE INSERT

FOR INTERNAL

CONNECTIONS

A B C D E F G H J K

A B C D E F G H J K

SOURCE I AND SOURCE II MUST

PRESENT THE SAME PHASE

ROTATION TO THE LOAD.

N

X

SOURCE II

Y

Z

POTENTIAL SENSING TRANSFORMERS 500 VA MIN

120 VAC, 60 HZ SECONDARIES

SAFETY LIFE FOR

!

11

cutouts, transformer (The .

KEY:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NC = NORMALLY

LS3

 

LS2

 

 

LS3 LS1

LS4

 

LS3

 

LS2

 

 

LS3 LS1

LS4

 

CLOSED

(NC)

 

(NO)

 

 

(NO) (NC)

(NC)

 

(NC)

 

(NO)

 

 

(NO) (NC)

(NC)

 

NO = NORMALLY

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OPEN

 

 

 

 

 

LS2

 

LS4 M

 

 

 

 

 

 

 

LS2

 

LS4

 

 

 

M = MOTOR

TRIP

 

 

 

 

 

R

CLOSE

TRIP

 

 

 

 

 

M

R

CLOSE

 

 

 

 

 

 

 

 

 

(NC)

 

R = RESISTOR

COIL

 

 

 

 

(NC)

 

(NO)

 

COIL

COIL

 

 

 

 

 

(NO)

 

 

COIL

 

1

2

3

4

5

6

7

8

9 10

 

 

1

2

3

4

5

6

7

8

9 10

 

 

 

 

L M N P R S T U V

 

 

A B C D E F G H J K

 

 

 

INTERNAL CONNECTION DIAGRAM:

INTERNAL CONNECTION DIAGRAM:C-INTERRUPTER # 2 C-INTERRUPTER # 1

1-75-S260