Cornelius 750 Pre-Mix manual Unit Without sealed evaporator tank

Models: 750 Pre-Mix

1 8
Download 8 pages 46.33 Kb
Page 3
Image 3
Unit Without sealed evaporator tank.

E.Pull ice bank control sensing bulb up out of holder in product coil basket and lay off to one side. BE CAREFUL NOT TO KINK CAPILLARY TUBE.

F.Disconnect anode wire from evaporator tank, then remove anode from holder in product coil basket. Discard old anode.

Unit Without sealed evaporator tank.

G.Disconnect agitator motor power cord.

H.Pull ice bank control sensing bulb up out of holder in product coil basket and lay off to one side. BE CAREFUL NOT TO KINK CAPILLARY TUBE.

I.Disconnect anode wire from evaporator tank, then remove anode from holder in product coil basket. Discard old anode.

J.Remove two screws on each side securing agitator motor to evaporator tank.

4.Disconnect product lines from back of dispensing valves sleeves. MAKE SURE LINES ARE LABELED FOR IDENTIFICATION SO THAT THEY MAY BE RECONNECTED TO PROPER VALVES.

5.Remove shank nuts from back of dispensing valves sleeves. Remove valves and sleeves, spacers, plate, and plate gasket from unit.

6.Unit without sealed evaporator tank.

A.Pull unit product inlet lines up through unit cabinet far enough to allow product coil basket and agitator motor to be lifted up and out of evaporator tank.

B.Very carefully, lift product coil basket and agitator motor up out of evaporator tank and lay them off to one side.

7.Unit with sealed evaporator tank.

A.Very carefully, lift product coil basket up out of evaporator tank and lay them off to one side.

IMPORTANT: If evaporator tank has hole in it allowing water to leak to inside of unit, hole may be repaired by using locally procured two-part epoxy patch.

8.Facing front of unit (dispensing valve side), remove left and rear lower access grilles for access to refrig- eration system.

9.Remove drip tray from unit.

10.Remove four screws above and three screws below lower front access grille securing front panel to unit.

11.Remove three screws above and one screw below lower left access grille securing left-side panel to unit.

12.Remove five screws securing left (facing dispensing valve side of unit) side corner securing front and left-side panels together.

13.Pull left and front side panels apart in preparation to route new SUCTION LINE ASS’Y (item 1) copper lines from lower part of unit to inside of evaporator tank.

Removal of Refrigerant. In starting work, be advised that the following warnings, cautions and notes are directly applicable:

WARNING: to avoid possible fatal electric shock or serious injury, disconnect electrical power from the unit before starting kit installation.

WARNING: To avoid electrical shock even after electrical power has been disconnected from the Unit, discharge the start capacitor by momentarily touching both terminals at the same time using an insulated screwdriver.

3

189159001

Page 3
Image 3