5. Remove any excess sealant.
Note: For
6.Mount the Transformer power supply under the counter, in a position to allow access to the electrical outlet and to allow the 24V power cord to reach the dispenser.
7.Install the drain hose to the ice bin drain fitting and route the drain hose to a permanent drain.
Free-Standing Dispenser
1.Install the 6“ legs to the dispenser cabinet if they are to be used.
2.Place the dispenser in the location selected. Be sure the dispenser is level. This is important to ensure that the bin drains properly.
3.Mount the Transformer power supply in a convenient location to allow access to the electrical outlet and to allow the 24V power cord to reach the dispenser.
4.Install the drain hose to the ice bin drain fitting and route the drain hose to a permanent drain.
SANITIZING PRODUCT COLD PLATE TUBING
Preparing the Cleaning Solution: Using a clean tank (tank system) or a
Preparing the Sanitizing Solution: Using a clean tank (tanks system) or a
STEP 1. WASH PRODUCT/SYRUP SYSTEMS
1.Using a clean tank (tank system) or a
Tank Systems.
A.Observe and note CO2 pressure setting on the tanks CO2 regulator, then
B.Connect detergent solution tank, pressurized at 60 to
C.Install bag valves (cut from empty
D.Place all syrup outlet tubes, with bag valves on their ends, in container containing detergent solution.
2.Flush the syrup system and dispensing valve as follows:
A.Place waste container under applicable dispensing valve.
B.Activate the dispensing valve for one minute to purge all syrup and flush out the syrup system.
EIMI Cornelius Inc; | 2 | 10/4/94 | |
Revised 10/8/03 | |||
|
|
166239001 Rev. Level 1