Sanitizing Prior to Initial Use

Sanitizing Prior to Initial Use

The beverage system must be cleaned and sanitized after installation is completed to safe guard against any possible contaminants which may have entered the system during transport or installation. Refer to the “Cleaning & Sanitizing the System” section of this manual for procedures.

Apply Sealant to Base & Countertop

If the optional legs are not used to raise the dispenser off the counter, the entire perimeter of the base must be sealed at the counter top with silicone (or other food grade approved sealant) in order to comply with N.S.F. standards. Refer to the template supplied in the Installation Kit.

Programming Portion

Control (optional)

a.Simultaneously, press and hold “S” (small) and “XL” (extra large) push button switches on the Coded Autoset Portion Control Module until the LED light in the lower right hand corner of the module starts blinking. Release the switches. The blinking LED indicates the programming mode is active.

b.Place the cup under the white mixing valve nozzle and push the selected size button (small, medium, large, or extra large). Hold the button in until the cup fills to the desired portion, then release the button. Repeat the above procedure for the remaining sizes.

c.After programming all the drink sizes, press and release the “cancel/pour” ▲▼ switch to return the Coded Autoset Portion Control to the operational mode. The blinking LED light will go out.

d.If at a future date, it is decided to change the portion size of the drinks, the individual sizes can be adjusted by the above procedure. It is not necessary to reprogram every size.

NOTE: The portion control has a full memory retention in case of a power failure.

SMALL MEDIUM LARGE EXTRA-LARGE

S Apply Sealant to Base & CountertopProgramming Portion M S  M  L  XL CANCEL/POUR ▲▼: L Brixing ConcentrateManual background XL Manual background

▲▼ Manual backgroundL.E.D.

CANCEL/POUR

CANCEL/POUR ▲▼:

a.Push and release cancel/pour button to stop the valve from dispensing.

b.Push and hold for a continuous pour.

Brixing Concentrate

The following procedures describe how to adjust the water to concentrate ratio (brix) according to taste. Contact your concentrate supplier for recommended brix ratios.

a.Remove the flavor strip cover above the dispense valves.

b.Sample the finished drink. Increase or decrease the water ratio by turning the water flow control screw clockwise (more water) or counterclockwise (less water) until the desired water to concentrate ratio is achieved. Repeat procedure on remaining valves.

c.Replace the flavor strip cover.

NOTE: If the flow control does not respond there may be debris caught between the internal ceramic spool and sleeve. Try dislodging the debris by pressing the dispense switch several times or turning the flow control adjustment screw all the way in and out several times.

6

Page 7
Image 7
Cornelius MJ32-4 PC Programming Portion Control optional, Brixing Concentrate, Sanitizing Prior to Initial Use, S M L Xl