Troubleshooting Guide

Problem

Probable Cause

Remedy

COMPRESSOR RUNS BUT

Condenser fan not running.

Check that the condenser fan is

NO COOLING. TRIPPING

 

running. If the fan is binding or

OVERLOAD.

 

turning slowly, an overload condition

(Compressor shell is hot to

 

will occur.

touch).

 

 

 

Inadequate air flow through

Air flow is top front in, exhaust out

 

the dispenser.

the rear. NEVER PLACE

 

 

ANYTHING ON TOP OF THE

 

 

DISPENSER. This will block the

 

 

airflow over heating the compressor

 

 

and causing it to trip the overload.

 

Blocked condenser fins.

Remove the rear bonnet and check

 

 

the condenser fins. If unit is run in a

 

 

dusty environment, condenser fins

 

 

can become clogged, stopping the air

 

 

flow.

 

 

Brush out and clean with vacuum.

 

Ambient air over 100°F 38°C.

If the dispenser is working in an

 

 

environment over 100° ambient or is

 

 

drawing in discharged air, during a

 

 

heavy period, the unit may trip the

 

 

overload.

 

Defective overload.

Overload works on shell temperature

 

 

and amperage draw and can be

 

 

defective. Replace as needed.

 

Defective compressor.

Refrigeration technician will verify if

 

 

the compressor is defective and needs

 

 

to be replaced.

UNIT IS DISPENSING

Insufficient water level in the

See the Start-up and Operation

CONCENTRATE ONLY

water bath.

Section of this manual. Be sure the

REFRIGERATION SYSTEM

 

water bath is filled to fill line.

HAS BEEN RUNNING FOR

 

 

EXTENDED PERIOD

Agitator motor not operating.

Check the agitator motor located on

WITHOUT SHUTTING OFF

 

the refrigeration deck. Be sure it is

FROZEN WATER COIL.

 

plugged in and receiving power.

 

 

Check that the impeller is not

 

 

obstructed. Replace if needed.

 

Improperly located ice bank

Melt the ice bank and check the

 

control sensor.

location of the sensing bulb. Be sure

 

 

it is all the way down to the bottom

 

 

of the tube.

16

Page 17
Image 17
Cornelius MJ31-4 PC, MJ32-4 PB No COOLING. Tripping, Overload, Anything on TOP, Refrigeration System, Without Shutting OFF