Trouble |
| Probable Cause |
| Remedy |
WATER PUMP CAPACITY | C. | Water filter clogged. | C. Replace water filter cartridge as | |
TOO LOW.(CONT’D) |
|
|
| instructed. |
| D. | Inoperative water pump. | D. | Call Service Person |
|
|
| ||
TROUBLESHOOTING REFRIGERATION SYSTEM |
|
| ||
|
|
|
|
|
Trouble |
| Probable Cause |
| Remedy |
|
|
|
|
|
COMPRESSOR DOES NOT | A. | Ice bank sufficient. | A. | Refrigeration not called for |
OPERATE. |
|
|
|
|
| B. Electrical power to cooling unit | B. Turn on electrical power to | ||
|
| turned off. |
| Cooling Unit. |
C.No cooling unit power source. Blown fuse or tripped circuit breaker.
C.Replace fuse or reset circuit breaker.
| D. | Inoperative compressor. | D. Call Service Person. |
COMPRESSOR OPERATES | A. | Cooling capacity is exceeded | A. Reduce amount of drinks drawn |
CONTINUOUSLY BUT DOES |
| by overdrawing. | per given time. |
NOT FORM SUFFICIENT ICE |
|
|
|
BANK. |
|
|
|
B.Cooling unit located in excessively hot area or air circulation through condenser coil is restricted
B.Relocate unit or check and if necessary, clean condenser coil as instructed.
312021002 | 20 |