Cornelius R-134A manual Troubleshooting Refrigeration System

Models: R-134A

1 26
Download 26 pages 33.21 Kb
Page 23
Image 23
TROUBLESHOOTING REFRIGERATION SYSTEM

Trouble

 

Probable Cause

 

Remedy

WATER PUMP CAPACITY

C.

Water filter clogged.

C. Replace water filter cartridge as

TOO LOW.(CONT’D)

 

 

 

instructed.

 

D.

Inoperative water pump.

D.

Call Service Person

 

 

 

TROUBLESHOOTING REFRIGERATION SYSTEM

 

 

 

 

 

 

 

Trouble

 

Probable Cause

 

Remedy

 

 

 

 

 

COMPRESSOR DOES NOT

A.

Ice bank sufficient.

A.

Refrigeration not called for

OPERATE.

 

 

 

 

 

B. Electrical power to cooling unit

B. Turn on electrical power to

 

 

turned off.

 

Cooling Unit.

C.No cooling unit power source. Blown fuse or tripped circuit breaker.

C.Replace fuse or reset circuit breaker.

 

D.

Inoperative compressor.

D. Call Service Person.

COMPRESSOR OPERATES

A.

Cooling capacity is exceeded

A. Reduce amount of drinks drawn

CONTINUOUSLY BUT DOES

 

by overdrawing.

per given time.

NOT FORM SUFFICIENT ICE

 

 

 

BANK.

 

 

 

B.Cooling unit located in excessively hot area or air circulation through condenser coil is restricted

B.Relocate unit or check and if necessary, clean condenser coil as instructed.

312021002

20

Page 23
Image 23
Cornelius R-134A manual Troubleshooting Refrigeration System