OWNER’S RECOMMENDED MAINTENANCE

OWNER’S RECOMMENDED MAINTENANCE

Maintenance Schedule

 

Task

D

M

Q

A

 

 

 

 

 

 

1.

Make sure CO2 cylinder regulator assembly

O

 

 

 

 

1800--psi gage indicator is not in shaded (‘change

 

 

 

 

 

CO2 cylinder’) portion of dial. If so, CO2 cylinder is

 

 

 

 

 

almost empty and must be replaced.

 

 

 

 

2.

CO2 regulators should be checked for proper pres-

 

S

 

 

 

sure settings periodically and adjusted as instructed.

 

 

 

 

3.

The carbonator tank liquid level (40 to 60-ounces)

 

S

 

 

 

pump cut--in and cut--out were adjusted at the

 

 

 

 

 

factory and should require no further adjustment. If

 

 

 

 

 

incorrect adjustment is suspected, call a Service

 

 

 

 

 

Person.

 

 

 

 

 

 

 

 

 

 

4.

Syrup systems should be sanitized every 90-days

 

 

S

 

 

following Sanitizer Manufacturer’s recommendations

 

 

 

 

 

as instructed in this manual.

 

 

 

 

 

 

 

 

 

 

5.

Ice water bath should be checked periodically as

 

O

 

 

 

instructed to make sure correct water is maintained

 

 

 

 

 

in water tank for maximum cooling.

 

 

 

 

 

 

 

 

 

 

6.

The drop--in refrigeration assembly condenser coil is

 

O

 

 

 

equipped with a washable air filter that must be

 

 

 

 

 

cleaned every 30-days as instructed .

 

 

 

 

7.

Carbonator water pump motor and carbonated wa-

 

S

 

 

 

ter circulating pump motor bearings must be oiled as

 

 

 

 

 

instructed in Service Manual (P/N 312021004).

 

 

 

 

8.

Carbonator water pump water inlet strainer screen

 

 

 

S

 

and double liquid check valve must be inspected

 

 

 

 

 

and cleaned at least once a year under normal cir-

 

 

 

 

 

cumstances and after any water system disruption

 

 

 

 

 

(plumbing work, earthquake, etc.).

 

 

 

 

 

 

 

 

 

 

9.

Clean and service Cooling Unit CO2 gas inlet check

 

 

 

S

 

valve. The CO2 gas check valve must be inspected

 

 

 

 

 

and serviced at least once a year under normal

 

 

 

 

 

conditions and after any CO2 system servicing or

 

 

 

 

 

disruption as instructed in Service Manual

 

 

 

 

 

(P/N 312021004)

 

 

 

 

 

 

 

 

 

 

Legend:

 

 

 

Daily

Weekly

Monthly

Quarterly Annually

Operator

Service Person

 