POWER SAVING SYSTEM
This monitor complies with VESA and ENERGY STAR® power saving requirements. The power saving system works only when used with VESA DPMS compliant PC’s and/or graphic controllers.
Table 2. Power Saving System
| VESA DPMS |
| Power Saving States | ||
Power Saving | Video | H. Sync. | V. Sync. | Power | Power Indicator |
Mode |
|
|
|
|
|
|
|
|
|
|
|
ON | Active | Yes | Yes | 115W (typical) | Lighting Green |
Blanked | No | Yes | Less than 10 W |
| |
Suspend | Blanked | Yes | No |
| Lighting Orange |
Active OFF | Blanked | No | No | Less than 3 W |
|
NOTE:
*When to switch the power Off during the monitor is in Active OFF mode, sometimes the power indicator lighting continues a few seconds. It is not failure.
PLUG & PLAY
This monitor complies with VESA DDC1/2B specifications. Plug & Play is a system, by which computer, peripherals (including monitors), and operating system manufacturers comply with for this
&Play functionality.
NOTE:
The Plug and Play function is only supported on INPUT1, and not supported on INPUT2.
SIGNAL CHECK
Your monitor is equipped with an automatic Signal Verification System. The Table 3 below outlines the operation of this system.
Table 3. Signal Check
Signal Condition | Indication of OSD | Power Indicator State | ||||
|
|
| ||||
Proper signal is detected | The OSD indicates the horizontal | The power indicator lights | ||||
by the monitor. | frequency and vertical frequency | green. |
|
|
|
|
| on the adjustment menu. |
|
|
|
|
|
No Sync. Signal is detected | The OSD indicates the message | After | 10 | seconds, | the | |
by the monitor. | “POWER SAVE” for 5 seconds | color | of | the | power | |
| after which time the unit will turn | indicator | will | turn | to | |
| into Power Saving Mode. | orange. |
|
|
| |
A video signal is applied | The OSD indicates the message | The power indicator | will | |||
to the monitor that is | “INVALID SCAN FREQ.”. | be illuminated as a solid | ||||
beyond the monitor scan |
| green color. |
|
| ||
range. |
|
|
|
|
|
|
17