Replacing the Deodorant filter (Every 12 Months)

FILTER REPLACEMENT

Cleaning and replacement schedule Make sure to pull power plug out prior to filter cleaning.

Replacing the Deodorant filter (Every 12 Months)

Open front cover, separate filter case out of the product and take Deodorant

filter out of filter case.

INSTALLATION METHODInstallation on the wall methodHanger (1 ea)

Remove vinyl packing of new filter, Put

Deodorant filter into the filter case.

 

Assemble filter case

 

into the product in

 

reverse of separation,

 

and closefront cover.

Filter Orders Pre- � medium � HEPA � Ag allergy shield � Deodorant

Cleaning and replacement schedule

Filters

Replacement

Cleaning

 

 

 

Pre-

Every 2~4 Weeks

Cleaning

Medium

Every 4 Months

Replacement

HEPA

Every 12 Months

Replacement

Ag Allergy Shield

Every 6 Months

Replacement

Deodorant

Every12 Months

Replacement

 

 

 

based on 24 hours/1 day automatic operation.

23

INSTALLATION METHOD

screw (6 ea) Contact A/S center to install the product on the wall.

Installation on the wall method

Fitting method

Install using wall-mounted panel saving some distance

from wall and ceiling right and left as shown in the picture. - When the product is used on the wall, it may contaminate

wall or ceiling.

- Be careful not to drop front cover and filter case down during maintenance or filter change.

- Do not pull power cord.

anchor (6 ea) Make sure the product is installed strongly on the screw of wall- mounted panel.

wall-mounting parts

Hanger (1 ea)

screw (6 ea)

anchor (6 ea)

rubber foot (2 ea)

Determine the place on which the product is going to be installed. Make a hole to install

hanger using a nail

 

and put an anchor in.

Place hanger on it

and fix it on the wall

 

using screw.

 

Place rubber foot on the 2 ea of round projection on the lower part of the back side of the product.