![](/images/new-backgrounds/1094679/9467933x1.webp)
•Empty water tank completely, replace cap, and run system to evacuate all wa- ter in supply lines.
•Store misting nozzle assembly by folding over dash of tractor.
•Clean debris from venting on rear of power unit.
•Clean the power unit thoroughly with mild soap and water.
•Ensure the power switch on the power unit is in the "OFF" position.
PROBLEM |
| CAUSE |
|
|
|
| |
Pump | Not |
| 1 .Switch | in OFF | Position | ||
Running |
| 2.Tractor | Key | in OFF Position | |||
Unit not Misting |
| 1 .Water | tank |
| is empty | ||
|
|
| 2.Adjustment |
| valve closed | ||
|
|
| 3.FilI cap not sealed | ||||
|
|
| 4.Drain | plug | not | sealed | |
|
|
| 5.Water | filter |
| needs replaced | |
|
|
| 6.Basket | filter | missing | ||
Water | streaming | from | 1 .Water | in air | supply lines | ||
Misting | Nozzle |
| (Tank | Overfull) |
| ||
|
|
| 2.Adjustment |
| valve setting | ||
|
|
| 3.Air filter needs | replaced | |||
Inconsistent Misting | 1 .Adjustment |
| valve changing | ||||
|
|
| )osition |
|
|
|
|
Water | Dripping | from | 1 .Drain | plug | not | seated | |
Drain Plug |
| 2.Drain | plug | seal | is missing or | ||
|
|
| damaged |
|
|
|
CORRECTION
1.Toggle Switch to ON Position 2.Tractor Key to ON Position
1.Fill tank with DRINKING WATER 2.Open adjustment valve 3.Properly seat fill cap 4.Properly seat drain plug 5.Replace water filter
6.Install basket filter
1.Drain tank and run system until only air is emitted from nozzle 2.Close adjustment valve 3.Replace air filter
1.Adjust valve to desired mist den- sity and tighten locking nut against power unit housing
1.Properly seat drain plug 2.Replace drain plug seal
17