Situation

Probable Cause

& Solution

 

The door opens but

1.

If the opener

lights blink, check the safety reversing sensor. See

page 23.

won't close:

2,

If the opener

lights do not blink and it is a new installation, check

the down force.

 

 

See Adjustment

Step 2, page 29. For an existing installation, see below.

Repeat the safety reverse test after the adjustment is complete•

The door reverses for no apparent reason and opener lights don't blink:

. Is something obstructing the door? Pull the red emergency release handle. Operate the door manually. If it is unbalanced or binding, call for professional garage door service.

2, Clear any ice or snow from the garage floor area where the door closes.

3.Review the force adjustment procedures on page 29.

4.If door reverses in the fully closedposition, decrease the travel limits (page 28).

Repeat safety reverse test after adjustments to force or travel limits. The need for occasional adjustment of the force and limit seffings is normal. Weather conditions in particular can affect doer travel.

The door reverses for no apparent reason

and opener lights blink for 5 seconds

after reversing:

Check the safety reversing sensor. Remove any obstruction or align the receiving eye. See page 23.

The opener light:

The opener strains or maximum force is

needed to operate door:

The opener motor

hums briefly, then won't work:

•..doesn't turn on:

Replace the light bulbs (75 watts maximum). Use a standard neck garage door opener bulb if regular bulb burns out,

•.. doesn't turn off:

Is the Light feature on?. Turn it off.

The door may be out of balance or the springs are broken. Close the door and use the emergency release to disconnect the trolley. Open and close the door manually. A properly balanced door will stay in any point of travel while being supported entirely by itssphngs, If it

does not, disconnect the opener and call a professionalgarage door sewiceman. Do not increase the force to operate the opener.

1.The garage door springs are broken. See above.

2.If the problem occurs on the first operation of the opener, door may be locked. Disable the doorlock. If the chain was removed and reinstalled, the motor may be out of phase. Remove the chain; cycle the motor to the down position. Observe the drive sprocket. When it turns in a clockwise direction and stops in the down position, reinstall the chain.

Repeat the safety reverse test after the adjustment is complete,

The opener won't

1. Use the emergency release to disconnectthe trolley. The door can be opened and closed

operate due to

manually. When the power is restored, press the Door Control push bar or button and

power failure:

trolley will automatically reconnect (unless trolley is in lockout position.) See page 32.

2.The Emergency Key Release accessory (for use on garages with no service door) disconnects the trolley from outside the garage in case of power failure.

The chain droops

It is normal

for the chain to droop

slightly in the closed door position. Use the

or sags:

emergency

release to disconnect

the trolley. If the chain returns to normal height when

 

the trolley is disengaged and the door reverses on a one-inch board, no adjustments

 

are needed (see page 11).

 