ASSEMBLY

NEUTRAL (N)

PURCHASEDi_-- 11A 3-WtRE CORD

120 VAC

HOT (H)

i

\

/--/-7/

GROUND (G)

FIGo 2

shock, However, local codes may vary widely Consult with a local electrician for grounding requirements in your area

CORD SETS AND CONNECTOR PLUGS 12o VOLTS DUPLEX RECEPTACLE

Use only high quality, well-insulated, extension cords with the 120-vott "duplex" type electrical receptacles,, All cord sets used should be rated 125 volts at 20 AC amps or

FIG. 3

4-Wire Cord Set

greater for most electrical devices Keep extension cords as short as possible, preferably less than I5 feet long to prevent voltage drop and wires from overheating

Y (Hot)

(Hot)

t20 VOLTS, 20 AND 30 AMP RECEPTACLES:

For the 120 volts, 20 amp locking type NEMA L5-20R receptacle, a well-insulated cord set wilh a NEMA L5-20P locking type connector plug must be properly connected to the receptacle and to the desired 120 volts, single phase, 60 Hz, AC load Cord sets should be rated 20 AC amperes at 125 votts (or greater) for most electrical devices (Fig 3)

°For 120 volts, 30 amp locking type NEMA L5-30R receptacle, a well-insulated cord set with a NEMA L5-30P locking type connector plug must be properly connected to the receptacle and the desired 120 volts, single phase, 60 Hz, AC load The cord set should be rated 30 AC amperes at 125 volts (or greater) for most electrical devices (Fig 3)

120/240 VOLTS, 30 AMP RECEPTACLE:

A t20/240 volts, 30 amp, locking type type mating connec-

tor plug (Fig 4) is required when using this receptacle A 4-wire cord set, rated 30 AC amperes at 250 voJts (or

greater), is required and must be connected to the plug and to the desired loads Order NEMA type L14-30P

/ ,_-/Grour}d

(Green)

FIGo 4

240 VOLTS, 50 AMP RECEPTACLE

This receptacle is rated 50 AC amperes at 250 volts You

need a 3-prong grounded connector plug with same rating to use with this outlet Although current capacity of outlet is rated at 50 amps, loads applied through this outlet should not exceed 333 amps or you will overload the generator,