w w w . d e l l . c o m s u p p o r t . d e l l . c o m

Other BIOS Error Messages

Table 13-3 explains the other BIOS error messages that can display.

Ta b l e 1 3 - 3 . O t h er B I O S E r r o r Me s s a g e s

Message

Problem

Suggested Solution

 

 

 

Following

The physical disk roaming

Reconfigure the array.

SCSI disk not

feature did not find the

 

found and no

physical disk with the

 

empty slot

displayed SCSI ID. No

 

available for

slot is available to map the

 

mapping it

physical drive. PERC 3

 

 

cannot resolve the

 

 

physical drives into the

 

 

current configuration.

 

Following SCSI IDs have the same data y, z

Channel x: a, b, c

The physical drive roaming feature found the same data on two or more physical drives on channel x with SCSI IDs a, b, and c. PERC 3 cannot determine the drive that has the duplicate information.

Remove the drive or drives that should not be used.

Unresolved

The PERC 3 is unable to

configuration

determine the proper

mismatch

configuration after

between disks

reading both NVRAM and

and NVRAM on

Configuration on Disk.

the adapter

 

Press <Ctrl><M> to run the BIOS Configuration Utility. Choose

Configure>New Configuration to create a new configuration.

CAUTION: This will delete any existing configuration.