Other Potential Problems

Table 13-4 describes other items that might cause problems.

Ta b l e 1 3 - 4 . O t h e r Po t e n t i a l P r o b l e ms

Topic

Information

 

 

Physical drive

To display the Media Error and Other Error options, select

errors

the Objects—>Physical Drive menu and press <F2> after you

 

select a physical drive. A Media Error is an error that occurred

 

while actually transferring data. An Other Error is an error that

 

occurs at the hardware level, such as a device failure, poor

 

cabling, bad termination, or signal loss.

 

 

Virtual sizing

The virtual sizing option enables RAID expansion. Virtual

 

sizing must be enabled to increase the size of a logical drive or

 

add a physical drive to an existing logical drive. To enable

 

virtual sizing, run the BIOS Configuration Utility by pressing

 

<Ctrl> <M> at bootup. Select Objects—>Logical Drive.

 

Then select View—>Update Parameters. Set virtual sizing to

 

Enabled.

 

 

PERC 3 Power

The maximum PERC 3 power requirements are 15 watts at

Requirements

5 v and 3 amps.

 

 

Windows NT®

Refer to the PERC 3 Operating System Driver Installation

does not detect

Guide for the chapter about Windows NT driver installation.

the PERC 3

 

 

 

Troubleshooting

209

Page 211
Image 211
Dell 3 manual Other Potential Problems, Describes other items that might cause problems, Topic Information