SCSI Connectors

The PERC 3/DC and PERC 3/DCL adapter has two types of SCSI connectors:

Two 68-pin high density internal connectors

Two 68-pin external ultra-high-density connectors

Only one connector type can be used for the SCSI channel at any one time.

SCSI Termination

PERC 3/DC and PERC 3/DCL uses active termination on the SCSI bus conforming to SCSI-2 and SCSI-3 specifications. Termination enable/disable is automatic through cable detection.

SCSI Firmware

The PERC 3/DC and PERC 3/DCL firmware handles all RAID and SCSI command processing and supports the feature listed in Table 5-8.

Ta b l e 5 - 8 . S C S I F i r mw ar e

Feature

Description

 

 

Disconnect/

Optimizes SCSI bus seek.

reconnect

 

 

 

Tagged command

Multiple tags to improve random access

queuing

 

 

 

Scatter/gather

A single command can transfer data to and from different

 

memory locations.

 

 

Multi-threading

Up to 255 simultaneous commands with elevator sorting

 

and concatenation of requests per SCSI channel

 

 

Stripe size

Variable for all logical drives: 2 KB, 4 KB, 8 KB, 16 KB,

 

32 KB, 64 KB, or 128 KB

 

 

Rebuild

Multiple rebuilds and consistency checks with user-

 

definable priority

 

 

PERC 3/DC and PERC 3/DCL Features

71

Page 73
Image 73