w w w . d e l l . c o m s u p p o r t . d e l l . c o m

4Select Enabled to enable Virtual Sizing.

After you have created a logical drive set, the partition of the drive should be as large as the virtual size of the logical drive. After you have created a logical array set, the drive partition can be as large as the full size of the logical drive. However, this is the full virtual drive size, not the actual physical drive size.

Physical Drive

Select Objects—>Physical Drive to select a physical device and to perform the operations listed in the table below. The physical drives in the computer are listed. Move the cursor to the desired device and press <Enter> to display the screen.

Table 11-5 displays the operations you can perform on the physical drives.

Ta b l e 1 1 - 5 . P h y s i c al D r i v e Me n u O p t i on s

Option

Description

 

 

Rebuild

Rebuilds the selected physical drive.

 

 

Format

Low-level formats the selected disk drive.

 

 

Force Online

Changes the state of the selected disk drive to online.

 

 

Force Offline/

Changes the state of the selected disk drive to offline.

Remove HSP

 

 

 

Make HotSpare

Designates the selected disk drive as a hot spare.

 

 

View Drive

Displays the drive properties for the selected physical device.

Information

 

 

 

View Rebuild

Indicates how much of the rebuild has been completed.

Progress

 

 

 

SCSI Command

Sets the number of queue tags per command. The options

Qtagging

are Disabled Command Tagging, 2 Queue Tags, 3 Queue

 

Tags, 4 Queue Tags, or Enhanced QTag Scheduling. The

 

default is Enhanced QTag Scheduling.

 

 

Transfer Speed

Selects the speed at which data is transferred. Displays a

Option

menu that contains the options Negotiation=Wide, and Set

 

Transfer Speed. The maximum transfer speed is 160M.

 

 

156

PERC 3 BIOS Configuration Utility

Page 158
Image 158