Ta b l e 1 3 - 1 . G e n er a l P r o b l e ms a n d S u g g es t e d S ol u t i on s

Problem

Suggested Solution

 

 

The following displays:

Make sure that termination power (TERMPWR)

Firmware

is being properly provided to each peripheral

device- populated channel.

Initializing...

Make sure that each end of the SCSI channel

 

 

chain is properly terminated using the

 

recommended terminator type for the peripheral

 

device. The channel is automatically terminated

 

at the PERC 3 card if only one cable is

 

connected to a channel.

 

Make sure that the PERC 3 controller is properly

 

seated in the PCI slot.

 

 

Why does a failed logical

To maintain the integrity of the DOS path

array still get a drive

statement.

assignment?

 

 

 

BIOS Boot Error Messages

Table 13-2 explains the error messages that can display when there is an error during bootup.

Ta b l e 1 3 - 2 . B I O S B o ot E r r o r M e s s a ge s

Message

Problem

Suggested Solution

Adapter BIOS

The PERC 3 BIOS is

Disabled. No

disabled. Sometimes

Logical Drives

the BIOS is disabled

Handled by BIOS

to prevent booting

 

from the BIOS. This is

 

the default when

 

cluster mode is

 

enabled.

Enable the BIOS by pressing <Ctrl> <M> at the boot prompt to run the BIOS Configuration Utility.

Host Adapter at

The BIOS cannot

Make sure PERC 3 is

Baseport xxxx

communicate with the

properly installed. Check

Not Responding

adapter firmware.

SCSI termination and

 

 

cables.

 

 

 

No PERC 3

The BIOS cannot

Make sure PERC 3 is

Adapter

communicate with the

properly installed.

 

adapter firmware.

 

Troubleshooting

205

Page 207
Image 207
Dell Bios Boot Error Messages, Ta b l e 1 3 2 . B I O S B o ot Error M e s s a ge s, Message Problem Suggested Solution