![](/images/new-backgrounds/1240668/24066825x1.webp)
PROBLEM |
| CAUSE | |
Unatomized or | 1. | Material too | heavy. |
spattered spray | 2. | Insufficient | air pressure. |
|
3. Fluid pressure too high.
CORRECTION
1. Thin material
2, Turn pattern control knob counter clockwise to increase
air pressure. Turn air valve control knob counter clockwise
to increase air pressure.
3.Turn fluid control knob clockwise to decrease fluid flow. If using in remote pressure feed mode decrease fluid pressure at paint tank.
4. Dried material on tip of 4, Clean. fluid nozzle or air jets of
air cap.
Inadequate | air | 1. Air valve | control | knob | |||||
delivery |
|
|
| partially | closed. |
|
| ||
|
|
| 2. Dried material in air jets | ||||||
|
|
|
| or air cap, |
|
|
| ||
|
|
| 3, Obstruction | in air inlst. | |||||
Excessive | fog | 1, Air pressure | too | high | for | ||||
|
|
|
| viscosity | of | fluid |
|
| |
|
|
| 2. | Too far from work |
| ||||
|
|
|
| surface. |
|
|
|
| |
Material | leaking from | 1, LOOSecup or foreign | sub- | ||||||
fluid inlet of cup. |
| stances | on!between | cup | |||||
|
|
|
| thread | and | fluid | inlet. |
| |
Material | leaking from | 1. Dried | material in | tip of | |||||
nozzle | when trigger is |
| nozzle. |
|
|
|
| ||
released |
| 2. | Loose | fluid | needle |
| |||
|
|
|
| adjustment | nut. |
|
|
1.Turn air valve control knob clockwise to open.
2.Clean.
3.Remove obstruction.
1.Reduce air pressure at air supply regalator, turn pattern
control knob clockwise, or turn fluid control knob counter
clockwise,
2.Adjust to proper distance.
1. Clean and tighten.
1.Clean
2.Tighten fluid needle adjustment nut,
13- ENG | D29783 |