Operating Procedures
Daily Start-Up Procedures
(_)Set the Auto-On/Off lever to the Off position.
(_)oCrheCkthe air compressor visually for any damage
obstruction.
(_CIose the drain valve.
(_)Check the oil level ofthe pump.
_tthonnect the air hose to the quick connect socket on
e regulator assembly by inserting the quick connect
plug on the air hose into the quick connect socket. The
quick connect socket collar will snap forward and lock
the plug intoplace providing an air tight seal between
the socket and plug. To release the air hose push the
collar back onthe quick connect socket.
(_Plug the power cord into the proper receptacle.
(_Turn the Auto-On/Off lever to the On-Auto position and
the compressor will startand build air pressure in the
tank to cut-out pressure and thenshut off automatically.
(_)Adjust the regulator to a PSI setting that isneeded for
your application and be sure itis within the safety
standards required to perform the task. If using a
pneumatic tool, the manufacturer should have
recommendations in the manual for that particular
tool on operating PSi settings.
Note: The air compressor isnow ready for use. The
following inflation and cleaning accessories packaged
with this unit should only be operated at maximum
pressure of 20-30 PSI: blow gun, tapered nozzle,
inflation needles, blow gun adapter.
Dally Shut-Down Procedures
1. Set the Auto-On/Off lever to the Off position.
2. Unplugthe power cord from the receptacle.
3. Setthe outletpressureto zeroon the regulator.
4. Removeany airtools or accessories. When draining
thetank, alwaysuse ear and eye protection, Drainthe
tankin a suitablelocation; condensation willbe present
inmost cases of draining.
5. Open thedrain valve allowing air to bleed from the
tank.After all of the air has bled from thetank, close
thedrain valve to prevent debris buildup in the valve,
When draining the tank, always use ear and eye protection.
Drain the tank ina suitable location; condensation will be
present in most cases of draining.
Water that remains inthe tank during storage will corrode
and weaken the air tank which could cause the tank to
rupture. To avoid serious injury, be sure to drain the tank
after each use or daily.