PROBLEM

 

CAUSE

 

CORRECTION

 

 

 

 

 

No or low

6.

Air in hose.

6.

Turn off the engine, then

pressure

 

 

 

the water source.

(initial use)

 

 

 

Disconnect the water

(continued)

 

 

 

source from the pump

 

 

 

 

inlet and turn the water

 

 

 

 

source on to remove all air

 

 

 

 

from the hose. When there

 

 

 

 

is a steady stream of

 

 

 

 

water present, turn water

 

 

 

 

source off. Reconnect

 

 

 

 

water source to pump inlet

 

 

 

 

and turn on water source.

 

 

 

 

Squeeze trigger to remove

 

 

 

 

remaining air.

 

7.

Choke lever in the

7.

Move choke to the "No

 

 

"Choke" position.

 

Choke" position.

 

8.

Throttle control lever is

8.

Move throttle control lever

 

 

not in the "Fast" position.

 

to the "Fast" position.

 

9.

High pressure hose is too

9.

Use high pressure hose

 

 

long.

 

under 100 feet.

 

 

 

 

 

Will not draw

1.

Wand not in low

1.

See How to Use Wand

chemicals

 

pressure.

 

paragraph in the

 

 

 

 

Operation Section.

 

2.

Chemical filter clogged.

2.

Clean filter.

 

3.

Chemical screen not in

3.

Insure end of chemical

 

 

chemical

 

hose is fully submerged

 

 

 

 

into chemical.

 

4.

Chemical too thick

4.

Dilute chemical. Chemical

 

 

 

 

should be the same

 

 

 

 

consistency as water.

 

5.

Pressure hose is too long

5.

Lengthen water supply

 

 

 

 

hose instead of pressure

 

 

 

 

hose.

 

6.

Chemical build up in

6.

Have parts cleaned or

 

 

chemical injector.

 

replaced by AWSC.

 

 

 

 

 

D25852

20- ENG

Page 20
Image 20
Craftsman D25852, 919.769060 owner manual Is a steady stream