INITIAL SET UP

Deli Shop Model 436 Setup Guide

INITIAL SET UP

Unpack and Inspect

1.Carefully remove the merchandiser from its shipping carton and place it on a level surface.

2.Inspect the outside of the merchandiser for dents, scratches, or any damage resulting from improper handling.

3.If the merchandiser has the optional door lock, the key will be in the coin return receptacle.

4.Inspect the inside of the cabinet. Observe the location and position of the packing material should you need to reuse it. Carefully remove all packing material.

IMPORTANT

If you see any damage when you unpack the merchandiser, file a claim immediately with the carrier.

5.Instructions for installing the optional Base Plate are included with the Base Plate Assembly when shipped.

6.Inspect the merchandiser’s electrical connectors and components.

Electrical Requirements

The merchandiser is supplied with a service cord for the country of use and is terminated in a grounding type plug. The wall receptacle used for this merchandiser must be properly polarized, grounded, and of the correct voltage. Operating the merchandiser from a source of low voltage will VOID YOUR WAR- RANTY. Each merchandiser should have its own electrical circuit and that circuit should be protected with a circuit breaker or fuse conforming to local regulations.

Voltage Check - Place the test leads of a voltmeter across the LINE (LIVE) and NEUTRAL ter- minals of the wall receptacle. The meter should indicate 110 - 130 volts ac for 120 volt, 60 Hz locations, or 220 - 240 volts ac for 230 volt, 50 Hz locations.

Polarity Check - Place the test leads of a voltmeter across the LINE (LIVE) and GROUND ter- minals of the wall receptacle. The meter should indicate 110 - 130 volts ac for 120 volt, 60 Hz locations, or 220 - 240 volts ac for 230 volt, 50 Hz locations.

Noise Potential Check - Place the test leads of a voltmeter across the NEUTRAL and GROUND terminals of the wall receptacle. The meter should indicate 0 volts ac. A measurement greater than 1.5 – 2.0 volts ac could result in problems for the merchandiser's electronic circuitry caused by electrical noise.

Any deviation from these requirements could result in unreliable performance from your merchandiser.