CRESTRON CNTV | Cresnet Television Control Unit |
Test Digital Inputs
Depressing "1" from the MRMT11 VersiPort Test Menu opens the MRMT11 VersiPort Digital Input Test Menu which appears on the screen as six lines of text.
MRMT11 VersiPort Digital Input Test Menu
1- VersiPort 1
2- VersiPort 2
3- VersiPort 3
4- VersiPort 4
0 - Return to previous menu
To initiate the VersiPort Digital Input Test for each pin in the DIGITAL IN/OUT port, depress the corresponding menu number. For example, to test pin 1, depress 1 on the keyboard.
The MRMT11 VersiPort Digital Input Test begins by the PC prompting the user to depress the space bar to initialize the test. As long as the VersiPort is detecting an active signal, an asterisk
(*)appears on the screen every quarter second. If the VersiPort is not detecting an active signal, a dash
Read Analog Inputs
Depressing "2" from the MRMT11 VersiPort Test Menu opens the MRMT11 VersiPort Display Analog Input Menu which appears on the screen as six lines of text.
MRMT11 VersiPort Display Analog Input Menu
1- VersiPort 1
2- VersiPort 2
3- VersiPort 3
4- VersiPort 4
0 - Return to previous menu
To initiate a reading of the VersiPort Analog Input for each pin in the DIGITAL IN/OUT port, depress the corresponding menu number. For example, to test pin 1, depress 1 on the keyboard.
The MRMT11 VersiPort Display Analog Input begins by the PC prompting the user to depress the space bar to initialize the reading. The actual value read from the VersiPort is displayed on the screen every quarter second. Acceptable input levels range between 0 and 5 volts or contact closure (equivalent to logic "0"). Readings are provided in a
Set Analog Input Thresholds
Depressing "3" from the MRMT11 VersiPort Test Menu opens the MRMT11 VersiPort Set
Analog Threshold Menu which appears on the screen as six lines of text.
R E M O T E C O N T R O L S Y S T E M S | 15 | DOC. 8105B |
|