Crimestopper Security Products TN-4004, TN-4003 Wiring, Pin 13 Empty Pin 14 Red 12 Volts Input

Models: TN-4003 TN-4004

1 12
Download 12 pages 13.15 Kb
Page 10
Image 10
Pin 13: Empty

WIRING

Pin 12 Orange: Alarm Trigger (-) Default* or Door Open/Close Input #1

A. Alarm Trigger*: Triggers alarm input of tracking device if received a negative input for 15 seconds or longer. This is connected to the negative siren output, if alarm has positive siren output use a relay to convert to negative.

B. Door Open/Close Input :This unit can be programmed for monitoring of door open and close. This configuration must be program see dealer for programming instructions.

Pin 13: Empty

Pin 14 Red: 12 Volts Input

This wire is the main power lead. It requires 12 volts constant power.

Pin15 Black: Chassis Ground Input

THIS WIRE MUST BE CONNECTED TO THE CHASSIS METAL OF THE VEHICLE. Scrape away any paint or dirt to ensure a good connection.

Pin 16 Black Ground Input

This wire is ground input from the back up battery.

Pin 17 Gray (Not Used)

Pin 18 White/Brown (-) Output

This wire can be programmed to be a ½ second pulsed output or a 3 second pulsed output.

Pin 19 Green/Yellow (-) Input

Ground this wire to trigger start up test on unit

PIN 20 White/Yellow (Not Used)