CONTROL MODULE & COMPONENT MOUNTING
Main Unit: The TrakNet unit has an internal power management program that monitors the vehicle power at all times. The internal power management program is continuously looking at the condition of the battery in order to detect the state of the vehicle operation. The Traknet unit determines the state of the vehicle power by detecting changes in the battery voltage over time. It is critical that the vehicle power be taken from a source as close to the battery as possible. Possible sources besides a direct connection to the battery is the main fuse block.
Back Up Battery: Securely mount the battery so it wont move around. It can be mounted in various positions because the battery is sealed and should not leak.
MOUNTING LOCATION
Module Mounting Location
The Traknet Unit is supplied with a 6 ft. power cable. The unit should be mounted so it will not be exposed to damage from people or objects. The cables that connect to the unit should also be routed to protect them from possible damage. The module has a mounting base or flange with four mounting holes. Normal installation is with these four holes and #6 or #8 sheet metal screws. The unit must be mounted where it will not be exposed to direct sunlight or excessive heat generated by the vehicle operation. Some examples of mounting locations include under the dash above the knee bolster, under center console, behind glove compartment, and in the trunk. If the optional battery is to be installed there should be room to mount the battery within 1 ft of the module.
The unit has a diagnostic wire and LED that will be used to verify operation by the installer. These items are normally not used by the owner.
4