Allied Telesis AT-FS750/24, AT-FS750/16 manual Troubleshooting, Chapter

Models: AT-FS750/24 AT-FS750/16 FS750/24 FS750/16

1 44
Download 44 pages 58.93 Kb
Page 39
Image 39
Troubleshooting

Chapter 3

Troubleshooting

This chapter contains information on how to troubleshoot the switch if a problem occurs.

Note

For further assistance, please contact Allied Telesis Technical

Support. Refer to “Contacting Allied Telesis” on page 14.

Check the POWER LED on the front of the switch. If the LED is off, indicating that the unit is not receiving power, do the following:

ˆEnsure that the power cord is securely connected to the power source and to the AC connector on the back panel of the switch.

ˆVerify that the power outlet has power by connecting another device to it.

ˆConnect the unit to another power source.

ˆUse a different power cord.

ˆVerify that the voltage from the power source is within the required levels for your region.

Verify that the LINK/ACT LED for each port is ON. If a LINK/ACT LED is

OFF, do the following:

ˆVerify that the end node connected to the port is powered on and is operating properly.

ˆVerify that the twisted pair cable is securely connected to the port on the switch and to the port on the end node.

ˆEnsure that the twisted pair cable does not exceed 100 meters (328 feet).

ˆVerify that you are using the appropriate category of twisted pair cable: Category 3 or better for 10 Mbps operation and Category 5 and Category 5E for 100 and 1000 Mbps operation.

Note

A 1000Base connection may require five to ten seconds to establish a link.