Crown CTS 4200 Advanced Features and Options, CTs Multi-Channel Power Amplifiers, page, Detent

Models: CTS 4200 CTS 8200

1 32
Download 32 pages 21.17 Kb
Page 15
Image 15
5.2.4 Channel Level Control

CTs Multi-Channel Power Amplifiers

5 Advanced Features

and Options

5.2.4 Channel Level Control

The signal level for each input can be attenu- ated accurately by adjusting the 21-step Level Control (see Section 4.2). Figure 5.2 shows the amount of attenuation in dB for each detent.

Note: Attenuation per detent varies with operat- ing mode since gain varies with operating mode. Attenuation amounts shown may vary ±6%.

ATTENUATION in dB

Detent
4/8 Ohm

70V

100V

 

 

 

 

0 (full CCW)

-68.31

-72.90

-71.02

 

 

 

 

1

-67.54

-72.06

-70.26

 

 

 

 

2

-32.23

-36.61

-34.90

 

 

 

 

3

-25.46

-29.74

-28.00

 

 

 

 

4

-21.83

-25.87

-24.22

 

 

 

 

5

-19.23

-23.20

-21.58

 

 

 

 

6

-17.12

-20.94

-19.40

 

 

 

 

7

-15.36

-19.02

-17.53

 

 

 

 

8

-13.76

-17.22

-15.79

 

 

 

 

9

-12.28

-15.53

-14.20

 

 

 

 

10

-10.84

-13.90

-12.62

 

 

 

 

11

-9.51

-12.32

-11.16

 

 

 

 

12

-8.28

-10.87

-9.81

 

 

 

 

13

-7.09

-9.45

-8.45

 

 

 

 

14

-6.30

-8.11

-7.22

 

 

 

 

15

-4.92

-6.70

-5.94

 

 

 

 

16

-3.82

-5.26

-4.63

 

 

 

 

17

-2.62

-3.70

-3.21

 

 

 

 

18

-1.35

-1.90

-1.66

 

 

 

 

19

-0.01

-0.01

-0.01

 

 

 

 

20 (full CW)

0.00

0.00

0.00

 

 

 

 

Figure 5.2 Level-control Attenuation per Detent

Operation Manual

page 15

Page 15
Image 15
Crown CTS 4200 Advanced Features and Options, CTs Multi-Channel Power Amplifiers, page, Channel Level Control, Detent