6 Specifications
Performance (continued)
Output Impedance | See Figure 6.5 |
|
|
Load Impedance (Note: Safe with all types of loads) |
|
Stereo | |
Bridge Mono | |
Parallel Mono |
Voltage Gain (8-ohm load, rated output at 1 kHz, maximum level setting)
0.775V sensitivity
1.4V sensitivity
26 dB sensitivity
124.6:1 ±6% or 41.9 dB ±0.5 dB 69.2:1 ± 6% or 36.8 dB ±0.5 dB 20:1 ±6% or 26 dB ±0.5 dB
Required AC Mains | 50/60 Hz; |
| able. 230 VAC, 50/60 Hz units can be used with 220 and 240 |
| VAC. 100 and 120 VAC units can draw up to 30 amps; 230 |
| VAC units can draw up to 15 amps. Current, voltage and fre- |
| quency requirements are provided on the unit’s back panel. |
|
|
Power Draw at Idle | 90 watts or less |
|
|
Construction |
|
|
|
Cooling | Internal heat sinks with |
| heat dissipation |
|
|
Dimensions |
|
Width
Height
Depth (behind mounting surface)
EIA Standard
3.5inch (8.9 cm) 16 inch (40.6 cm)
Weight
Center of gravity is 6 inches (15.2 cm) behind the front mounting surface.
120 VAC, 60 Hz Units
Net
Shipping
100 VAC, International Units
Net
Shipping
120 VAC, International Units
Net
Shipping
230 VAC, International Units
Net
Shipping
55 pounds, 1.5 ounces (25.0 kg)
63 pounds, 10 ounces (28.9 kg)
54 pounds, 5 ounces (24.7 kg)
63 pounds, 0.5 ounces (28.6 kg)
55 pounds, 1.5 ounces (25.0 kg)
63 pounds, 10 ounces (28.9 kg)
53 pounds, 6 ounces (24.2 kg)
61 pounds, 15 ounces (28.1 kg)
Operation Manual | page 17 |