5 Advanced Features
and Options
NOTE: For detailed information about these Crown amplifier features, please consult the Crown Amplifier Application Guide, available on the Crown website at www.crownaudio.com
5.1 Protection Systems
Your Crown amplifier provides extensive pro- tection and diagnostic capabilities, including ODEP and IOC.
5.1.1Output Device Emulation Protection (ODEP)
Crown invented ODEP to solve two long stand- ing problems in amplifier design: To prevent amplifier shutdown during demanding opera- tion and to increase the efficiency of output cir- cuitry.
To do this, Crown established a rigorous pro- gram to measure the safe operating area (SOA) of each output transistor before installing it in an amplifier. Crown also designed intelligent circuitry to simulate the instantaneous operat- ing conditions of those output transistors. Its name describes what it does: Output Device Emulation Protection or ODEP. It not only simu- lates the operation of the output transistors but it also compares their operation to their known SOA. If ODEP sees that more power is about to be asked of the output devices than they are capable of delivering under the present condi- tions, ODEP immediately limits the drive level until it falls within the SOA. Limiting is propor- tional and kept to an absolute
This level of protection enables Crown to increase output transistor utilization while greatly increasing amplifier reliability.
Finally, this onboard intelligence is monitored in two ways. First, the front panel ODEP indica- tors show whether the amplifier is functioning correctly or if ODEP is limiting the drive level. Second, ODEP data is fed to the PIP connector at the back of the amplifier so advanced PIP modules like the
(The
5.1.2IOC (Input Output Compara-
tor)
The IOC circuit compares the output signal of the amplifier with the input signal. If there is any difference other than gain, then it is consid- ered distortion and the indicator comes on. The LED indicator will come on whenever there is distortion of 0.05% or more. An IOC condition may also be sensed by an IQ PIP module installed in
IOC is designed to report any form of distor- tion. IOC not only checks the waveform for dis- tortion, but also reports input overload and even a protective action that mutes or shuts down an amplifier. With all of these features, IOC monitors the entire amplifier. When the IOC indicator is off the amplifier is definitely opera- tional and undistorted. IOC provides an
5.2 Circuit Designs
5.2.1 Grounded Bridge
Grounded Bridge is the name of Crown's unique
The power supply bridge rectifier is not ground referenced, and the transformer secondary is not
Composite output devices are arranged to func- tion as gigantic NPN and PNP devices. Each output stage has two composite NPN and two composite PNP devices. The devices con- nected to the load are referred to as
ground are referred to as
Crown's Grounded Bridge design delivers large voltage swings without stressing output tran- sistors. The results are higher efficiency, lower distortion and superior reliablility.
5.2.2 Variable Impedance (VZ)
VZ is the name of Crown's patented articulated power supply technology. This innovative tech- nology permits us to pack large amounts of power into a compact package while achieving
An amplifier power supply must be large enough to handle both the maximum voltage and maximum current necesary for the ampli- fier to drive its rated power into a specified load. In order to meet this requirement, most conventional supplies are heavy, large, and produce lots of heat. In contrast, the VZ supply gets more current AND voltage out of a smaller, lighter, and more efficient package by dynami- cally adapting to both signal and load require- ments in
The VZ supply is divided into two segments. When the output stage requires
With VZ, you get not only maximum power and safety, but you also get the best power match- ing to your load.
page 14 | Operation Manual |