6 Specifications
Minimum Guaranteed Power | 120VAC, 60 Hz Units | 100VAC International | 120 VAC International | 230VAC International |
(see page 18 for complete power specifications) |
| Units | Units | Units |
|
|
|
|
|
Power in watts per channel,1 kHz, 0.1% THD |
|
|
|
|
|
|
|
|
|
Stereo mode with both channels driven |
|
|
|
|
2 ohms per ch. | 1800W | 1460W | 1490W | 1520W |
4 ohms per ch. | 1565W | 1300W | 1300W | 1325W |
8 ohms per ch. | 1120W | 980W | 985W | 965W |
|
|
|
|
|
|
|
|
|
|
4 ohms | 3505W | 2835W | 2980W | 2800W |
8 ohms | 3140W | 2625W | 2600W | 2515W |
|
|
|
|
|
|
|
|
|
|
1 ohm | 3555W | 2820W | 2980W | 2910W |
2 ohms | 3190W | 2585W | 2600W | 2565W |
|
|
|
|
|
Performance (120V AC units in stereo mode with 8 ohm load) |
|
|
|
|
|
|
|
|
|
Frequency Response |
|
|
|
|
(at 1 watt, 20Hz - 20 kHz) see Figure 6.3 | ± 0.1 dB |
|
|
|
|
|
|
|
|
Phase Response |
|
|
|
|
(at 1 watt, 10Hz - 20 kHz) see Figure 6.6 | ±10° |
|
|
|
|
|
|
|
|
Signal to Noise Ratio below full bandwidth power |
|
|
|
|
20 Hz to 20 kHz | >100 dB |
|
|
|
>105 dB |
|
|
| |
|
|
|
|
|
Total Harmonic Distortion (THD) |
|
|
|
|
at rated power, from 20 Hz to 1 kHz | < 0.05% |
|
|
|
at rated power, at 20 kHz | < 0.1% |
|
|
|
|
|
|
|
|
Intermodulation Distortion (IMD) |
|
|
|
|
60 Hz and 7 kHz at 4:1,from 368 milliwatts to full rated output | < 0.05% |
|
|
|
|
|
|
|
|
Damping Factor |
|
|
|
|
10 Hz to 400 Hz See Figure 6.4 | >1000 |
|
|
|
|
|
|
|
|
Crosstalk |
|
|
|
|
(below rated power, 20 Hz to 10 kHz) | see Figure 6.7 |
|
|
|
|
|
|
|
|
Controlled Slew Rate | > 30 volts/microsecond |
|
|
|
|
|
|
|
|
Input Impedance nominally balanced, nominally unbalanced | 20 k ohms, 10 k ohms |
|
|
|
|
|
|
|
|
page 16 | Operation Manual |