TABLE 7.4a: CROWN CONCENTRIC 60/100 VENT COMPONENTS

(VENT OPTION 1)

 

 

 

USED ON

 

CROWN PN

DESCRIPTION

SIZE

VENT

COMMENTS

 

 

 

OPTION #

 

230521

80/125 x 60/100mm REDUCING

80/125 x

1

INCLUDED WITH STANDARD

ELBOW

60/100mm

BWC070/090/120

 

 

 

 

 

 

 

230520

TERMINAL SECTION

60/100mm

1

INCLUDED WITH STANDARD

BWC070/090/120

 

 

 

 

 

 

 

 

 

230522

WALL GROMMET

60/100mm

1

INCLUDED WITH STANDARD

BWC070/090/120

 

 

 

 

 

 

 

 

 

230505

39” STRAIGHT

60/100mm

1

OPTIONAL - MAY NOT BE CUT

 

 

 

 

 

230504

78” STRAIGHT

60/100mm

1

OPTIONAL - MAY NOT BE CUT

 

 

 

 

 

230506

19 1/2” STRAIGHT

60/100mm

1

OPTIONAL - CAN BE CUT

 

 

 

 

 

230507

90 DEGREE ELBOW

60/100mm

1

OPTIONAL

 

 

 

 

 

230508

45 DEGREE ELBOW

60/100mm

1

OPTIONAL

 

 

 

 

 

230515

39” STRAIGHT

80/125mm

1

OPTIONAL - CAN BE CUT (Note #1)

 

 

 

 

 

Note #1: On 60/100mm vent systems, this may only be used between the boiler and the first 80/125 x 60/100 Reducing elbow (see text).

TABLE 7.4b: CROWN CONCENTRIC 80/125 VENT COMPONENTS

(VENT OPTIONS 3,6)

 

 

 

USED ON

 

CROWN PN

DESCRIPTION

SIZE

VENT

COMMENTS

 

 

 

OPTION #

 

230527

90 DEGREE EL (STANDARD)

80/125mm

3,6

 

 

 

 

 

 

230528

90 DEGREE EL (SWEEP)

80/125mm

3,6

 

 

 

 

 

 

230526

45 DEGREE EL

80/125mm

3,6

 

 

 

 

 

 

230517

19 1/2” STRAIGHT

80/125mm

3,6

CAN BE CUT

 

 

 

 

 

230515

39” STRAIGHT

80/125mm

3,6

CAN BE CUT

 

 

 

 

 

230518

39” STRAIGHT

80/125mm

3,6

MAY NOT BE CUT

 

 

 

 

 

230519

78” STRAIGHT

80/125mm

3,6

MAY NOT BE CUT

 

 

 

 

 

230525

TELESCOPING STRAIGHT

80/125mm

3,6

ADJUSTABLE FROM 12-1/2” TO 16-1/2

 

 

 

 

 

230531

HORIZONTAL TERMINAL

80/125mm

3

 

 

 

 

 

 

230540

SNORKEL KIT

80/125mm

3

(NOTE #1)

 

 

 

 

 

230532

VERTICAL TERMINAL

80/125mm

6

(NOTE #2)

 

 

 

 

 

230533

FLAT ROOF FLASHING

80/125mm

6

 

 

 

 

 

 

230535

SLOPED ROOF FLASHING

80/125mm

6

(NOTE #3)

 

 

 

 

 

230530

SUPPORT ELBOW WITH

80/125mm

6

(NOTE #4)

CHIMNEY CHASE BRACKET

 

 

 

 

 

 

 

 

 

230536

SUPPORT BAND

80/125mm

3,6

 

 

 

 

 

 

Table 7.4b Notes:

1)Snorkel kit includes parts needed to offset terminal on exterior wall by up to 46”.

2)Vertical terminal can be used with either of the roof flashings listed beneath it.

3)Sloped roof flashing suitable for roof angles between 25 and 45 degrees.

4)Used at base of vertical run inside unused masonry chimney.

15

Page 17
Image 17
Crown Boiler BWC151 manual Vent Option