V Mounting The Boiler

CAUTION

This boiler weighs approximately 110 pounds:

Two people are required to safely lift this boiler onto the wall mounting hook.

Make sure that wall mounting hook is anchored to a structure capable of supporting the weight of the boiler and attached piping when filled with water.

Jurisdictions in areas subject to earthquakes may have special requirements for supporting this boiler. These local requirements take precedence over the requirements shown below.

Mounting Steps:

1)If the boiler is installed on a framed wall, minimum acceptable framing are 2 x 4 studs. The boiler mounting holes are on 11-5/8” centers. Usually the wall studs will be on 16” centers. In such cases, both boiler bracket mounting holes must be anchored to ¾” Plywood, horizontal 2 x 4s anchored to the studs, or some other framing system capable of supporting the boiler. Attachment of either bracket hole to wallboard alone is unacceptable.

2)When mounting this boiler directly onto studs covered with 1/2” wall board, 5/16 x 2” lag screws are recommended. When the boiler is attached to other types of construction, such as masonry, use fasteners capable of supporting the weight of the boiler and attached piping in accordance with good construction practice and applicable local codes.

3)Make sure that the surface to which the boiler is mounted is plumb.

4)Before mounting the boiler, make sure that wall selected does not have any framing or other construction that will interfere with the vent pipe penetration.

5)Tape the paper template to the wall in the chosen location. Be sure to level the template.

6)Pre-drill two holes in the center of the “oval” slots on the mounting bracket sized for the hardware being used.

7)Mount the bracket to the wall. Be sure to level the bracket by adjusting the screw in the vertical slot.

8)Pre-drill the remaining hole in the mounting bracket and secure the final screw.

9)Cut the opening in the wall for the vent system. The recommended hole diameter for the standard 60/100mm venting is 4-3/8”.

10)Hang the boiler on the wall bracket as shown in Figure 5.2.

11)Verify that the front and sides of the boiler are plumb.

12)See Section VII (“Venting) for instructions on attaching the vent system to the boiler.

13)A hot water boiler installed above radiation level or as the Authority having jurisdiction,

must be provided with a low water cutoff device either as a part of the boiler or at the time of installation.

7

Page 9
Image 9
Crown Boiler MWC116ELT, MWC Series, MWC116ENL, MWC116ELL, MWC116ENT manual Mounting The Boiler

MWC116ENL, MWC116ELL, MWC116ELT, MWC116ENT, MWC Series specifications

Crown Boiler's MWC Series represents a commendable choice in the realm of residential and light commercial heating solutions. Specifically, models like the MWC116ENT, MWC116ELT, MWC116ELL, and MWC116ENL stand out due to their exceptional performance, reliability, and innovative features.

At the core of the MWC Series lies a robust cast iron boiler construction designed to withstand the test of time. This material not only provides durability but also enhances heat retention, thereby increasing the system's efficiency. Each model in this series is designed for natural gas or propane fuel types, ensuring flexibility based on availability and user preference.

A notable feature of the MWC116 models is the efficient heat exchanger, which enables rapid heating of water for both space heating and domestic hot water applications. With a heating capacity of 116,000 BTUs, these boilers deliver ample warmth for mid-sized homes or light commercial settings, making them a versatile option for various applications.

The MWC116ENT model is equipped with an energy-efficient electronic ignition system, which enhances reliability and efficiency. This technology reduces energy consumption, providing users with cost savings on their utility bills. Similarly, the MWC116ELT model boasts an integrated aquastat that regulates water temperature, ensuring optimal performance and comfort.

For those requiring increased venting options, the MWC116ELL model includes advanced horizontal venting capabilities, allowing for flexible installation in various environments. This feature aids in overcoming space limitations and facilitating optimal combustion conditions. The MWC116ENL, on the other hand, features a low NOx emissions configuration, making it an environmentally conscious choice for users concerned about their carbon footprint.

User-friendly controls are a characteristic hallmark of the MWC Series, enabling straightforward operation and easy adjustments. The boilers come equipped with a digital display that provides critical system information and diagnostics, streamlining maintenance efforts.

Overall, the Crown Boiler MWC Series, particularly models like the MWC116ENT, MWC116ELT, MWC116ELL, and MWC116ENL, offer an impressive blend of efficiency, flexibility, and advanced technology. These units are designed to meet contemporary heating demands while ensuring sustainable operation, making them a wise investment for comfort and performance in residential and light commercial applications alike. With reliable construction and innovative features, the MWC Series remains a top choice for those seeking effective heating solutions.