Installing the VoIP Loudspeaker Amplifier 25

2.5 Restore the Factory Default Settings

When troubleshooting configuration problems, it is sometimes convenient to restore the device to a known state.

Each loudspeaker amplifier is delivered with factory set default values for the parameters indicated in Table 2-13. Use the RTFM switch on the loudspeaker amplifier face to restore these parameters to the factory default settings.

When you use the RTFM switch, the factory default settings are restored for only the parameters indicated in Table 2-13. The other parameters in the current loudspeaker amplifier configuration will remain unchanged.

 

Table 2-13. Factory Default Settings

 

 

Parameter

Factory Default Setting

 

 

IP Addressing

static

 

 

IP Address

192.168.3.10

 

 

Web Access Username

admin

 

 

Web Access Password

admin

 

 

Subnet Mask

255.255.255.0

 

 

Default Gateway

192.168.3.1

 

 

To restore these parameters to the factory default settings:

1.Press and hold the RTFM switch for 20 seconds.

2.The loudspeaker amplifier will beep after one second. Continue to hold the switch until the loudspeaker amplifier beeps again after 20 seconds.

3.Release the switch. The following occurs:

A voice message announces that the factory default settings are being restored.

Once the settings are restored, a voice message announces the restored default IP address:

192.168.3.10

A voice message announces that the loudspeaker amplifier is rebooting.

The loudspeaker amplifier reboots.