CyberResearch® Digital I/O | UCERB 24 |
Each DIP switch sets the configuration of one relay group. The DIP switch labeled A configures relays 1 to 8, the switch labeled B configures relays 9 to 16, the switch labeled CL configures relays 17 to 20, and the switch labeled CH configures relays 21 to 24 (Figure
A
Configures relays B
Configures CL
Configures CH
Figure
Port A consists of relays 1 through 8, Port B consists of relays 9 through 16, Port CL consists of relays 17 through 20, and Port CH consists of relays 21 through 24.
Remove from the enclosure to access the
To change the configuration of a switch, you must first remove the UCERB 24 from the enclosure.
Relay control logic polarity
Configure the
INVERT
A
B
CL
S1 CH
Figure
INVERT mode: when "0" is written or read back via the USB bus, the relays are energized.
Switch settings for polarity can be read back via software through the USB bus. Switch settings for S1 do not affect the
Relay
Configure the
PULL DOWN PULL UP
A
B
CL
S2 CH
Figure
Power to the UCERB 24 is provided with the 9 V, 3 A external power supply. You must connect the the external power supply before connecting the USB connector to the UCERB 24.
To connect the power supply to your UCERB 24, do the following:
1.Connect the external power cord to the power connector labeled POWER IN on the UCERB 24 enclosure (PWR IN on the board). Refer to Figure
2.Plug the AC adapter into a power outlet.