UCERB 24 | CyberResearch® Digital I/O |
Pull-up/pull-down switch (S2)
The
PULL DOWN PULL UP
A
B
CL
S2 CH
Figure
The switch labeled A configures relays 1 through 8, the switch labeled B configures relays 9 through 16, the switch labeled CH configures relays 17 through 20, the switch labeled CL configures relays 21 through 24.
PULL UP: the relay energizes at
PULL DOWN: the relays are not energized at
Use InstaCal to read the current
Screw terminals
Connect external devices to the relay contacts using the UCERB 24 board's 24 sets of screw terminals. Each relay has a normally closed (NC), common (C), and normally open (NO) contact. Figure
NC C NO
Figure
Each screw terminal is identified with a label on the board and on the underside of the enclosure lid.
Caution! Before connecting wires to the screw terminals, turn off the power to the UCERB 24, and make sure that the signal wires do not contain live voltages.
Use
Caution! Keep the length of stripped wire at a minimum to avoid a short to the enclosure! When connecting your field wiring to the screw terminals, use the strip gage on the terminal strip, or strip to 5.5 - 7.0 mm (0.215" to 0.275") long.
Daisy chaining additional relays to the UCERB 24
Daisy chained CyberResearch products connect to the USB bus through the
USB 2.0 port or USB 1.1 port on your computer.
Other CyberResearch products are USB 1.1
12 Mb/s. The throughput rate is shared by all devices connected to the USB bus. Use the supplied cable or an equivalent cable when daisy chaining CyberResearch products.
Use
To daisy chain two or more UCERB 24 relay boards, follow the steps below. This procedure assumes
you already have one UCERB 24 connected to a computer and to an external power source. The UCERB 24 already connected to the computer is referred to as the connected module. The UCERB 24 you
want to daisy chain to the connected board is referred to as the new module.