UCERB 24 | CyberResearch® Digital I/O |
Chapter 3
Functional Details
Internal components
The UCERB 24 has the following internal components, as shown in Figure
Two (2) USB connectors
Two (2) external power connectors
USB LED
PWR LED
Screw terminals
USB IN POWER IN
USB POWER
OUT OUT
PWR LED
USB LED
Screw terminals
Figure
USB in connector
The USB out connector is labeled USB IN on the board and enclosure.
The USB IN connector is a USB 2.0
USB out connector
The USB out connector is labeled USB OUT on the board and enclosure.
The USB OUT connector is a downstream hub output port intended for use with other CyberResearch products only. The USB hub is
For information on daisy chaining to other CyberResearch products, refer to Daisy chaining additional modules to the
External power connectors
The UCERB 24 has two external power connectors labeled POWER IN and POWER OUT on the enclosure. The POWER IN connector is labeled PWR IN and P19 on the board, and the POWER OUT connector is labeled PWR OUT and P20 on the board.
Connect the POWER IN connector to the supplied +9 V external power supply. External power is required to operate the UCERB 24. The POWER OUT connector lets you power additional daisy
chained products from a single external power supply. Depending on your load requirements, daisy chained products may require a separate power supply. Refer to "Power limitations using multiple UCERB 24 devices"