CyberResearch® Digital I/O | UCERB 24 |
Chapter 4
Specifications
Typical for 25 °C unless otherwise specified.
Specifications in italic text are guaranteed by design.
Output specifications
|
|
| Table |
|
|
| |
Number of relays | 24 | ||
Relay configuration | 2 banks of 8 and 2 banks of 4 | ||
Contact configuration | 24 Form C (SPDT) Normally Open, Normally Closed and Common available at screw | ||
|
|
| terminals |
Contact rating | 6 A @ 240 VAC or 28 VDC resistive | ||
Contact resistance | 100 milliohms max (initial value) | ||
Operate time | 10 milliseconds max | ||
Release time |
| 5 milliseconds max | |
Vibration |
| 10 to 55 Hz (amplitude 1.5 mm) | |
Shock |
| 10 G (11 milliseconds) | |
Dielectric isolation | 300 VAC, 50/60 Hz (1 minute) | ||
(between relay open |
| ||
contact) |
|
| |
Dielectric isolation | 500VAC, 50/60 Hz (1 minute) | ||
(between PCB output |
| ||
lines) |
|
| |
Life expectancy | 10 million mechanical operations, min | ||
Power on |
| S2 = | Energized. NO in contact with Common |
state |
|
| |
|
| S2 = | Not energized. NC in contact to Common |
|
| pull- |
|
|
| down |
|
Relay control logic | |||
polarity |
| for polarity can be read back via software through the USB bus. Switch settings do not | |
|
|
| affect the power on condition. |
|
|
| USB bus, relays are not energized. Invert mode, when "0" is written or read back via the |
|
|
| USB bus, relays are energized. |
|
|
| Settings can be read back via software. |
|
|
| mode on power up. |
CyberResearch, Inc. | 19 |
25 Business Park Drive | P: (203) |
Branford, CT USA | www.cyberresearch.com |